1.1

 

Default values of operating parameters 

 

Function Default 

Values 

Scanning Mode Selection 

Trigger mode 

Header and Trailer 

None 

Good Read Beeper Tone Selection 

2.3KHz/50 msec (medium) 

Code Identifier Transmitting 

Disable 

 

 

1.2

 

Predefined barcode identifiers 

 

Function Default 

Values 

Code 39 Barcode Identifier Code 

ITF 2 of 5 Barcode Identifier Code 

Chinese Post Code Identifier Code 

UPC-E Barcode Identifier Code 

UPC-A Barcode Identifier Code 

EAN-13 Barcode Identifier Code 

EAN-8 Barcode Identifier Code 

FF 

Coda bar Barcode Identifier Code 

Code 128 Barcode Identifier Code 

Code 93 Barcode Identifier Code 

MSI Barcode Identifier Code 

Industry 2 of 5 Identifier Code 

IATA Identifier Code 

 

 

1.3

 

Default values of decoding parameters 

 

Function Code Default 

Value 

Code 39 

Enable 

ITF 2 of 5 

Enable 

Chinese Post Code 

Disable 

UPC/EAN/JAN Enable 

Codabar Enable 

MSI/PLESSY Disable 

Code 128 

Enable 

Code 93 

Enable 

ITAT Disable 

EAN-128 Disable 

Industry 2 of 5 

Disable 

Italian Pharmacy 

Disable 

Reading codes 

Selection 

ISSN/ ISBN 

Disable 

Codes Standard 

Start/stop characters 

Not transmitting 

Code 39 

Check digit 

Disabled 

Length 6-32 

digits 

 
 

Interleaved 

2 of 5 

Check digit 

Disable 

Length 8~32digits 

Chinese Post

Code 

Check digit 

Transmit 

Format All 

Addendum Disable 

UPC-E=UPC-A Disabled 

UPC-A leading digit 

Transmit 

UPC-A check digit 

Transmit 

UPC-E leading digit 

Transmit 

UPC/EAN/JAN

UPC-E check digit 

Transmit 

Type Standard 

Start/stop characters

A, B, C, D 

Coda bar 

Length 6~32 

digits 

Code 128 

FNC 2 append 

Disable 

Length Variable 

MSI 

Check digit 

Double check but 

not transmit 

Italian Pharmacy Transmit "A" Character

Not transmitting 

Industry 2 of 5

Length 

6~32 digits 

 
 

© Baracoda 2004 

 Page 3/22 

Summary of Contents for BC2604

Page 1: ...y of our product information however we accept no responsability for errors or omissions including but not limited to the implied warranties of merchantability and fitness for a particular purpose We shall not be liable for errors contained herein or for incidental consequential damages in connection with the furnishing performance or use of this material Specifications or version may be subject to ...

Page 2: ...to change without notice The actual specification and version are based on the product delivered INTRODUCTION Scanning a series of programming bar code labels can configure the scanner The scanner must be properly powered before programming During the programming mode the scanner will acknowledge a good and valid reading with a short beep It will give long beeps for either an invalid or bad readin...

Page 3: ...Code 9 parameters setting 9 IInterleaved 2 of 5 parameters setting 9 Chinese post code parameters setting 10 Codabar Monarch parameters setting 10 UPC EAN JAN parameters setting 11 UPC EAN JAN parameters settings Cont d 13 Code 128 parameters setting 13 UCC EAN128 parameters setting 13 Industry 25 parameters setting 14 Msi Plessy setting 14 Italian pharmacy parameters setting 15 Barcode length set...

Page 4: ...e L MSI Barcode Identifier Code P Industry 2 of 5 Identifier Code R IATA Identifier Code T 1 3 Default values of decoding parameters Function Code Default Value Code 39 Enable ITF 2 of 5 Enable Chinese Post Code Disable UPC EAN JAN Enable Codabar Enable MSI PLESSY Disable Code 128 Enable Code 93 Enable ITAT Disable EAN 128 Disable Industry 2 of 5 Disable Italian Pharmacy Disable Reading codes Sele...

Page 5: ...e Baracoda 2004 Page 4 22 2 Program procedure using barcode menus Read Start of configuration Label SET ALL DEFAULTS SET GENERAL CONFIGURATION SET SYMBOLOGIES SET DATA EDITING FINISH Read End of configuration Label YES NO END START ...

Page 6: ...ngs The reading of the Default settings label turns all the parameters back to default settings When you intend to turn your scanner back to default parameter please scans the Start of configuration label first then scan Default settings label and finally scan the End of configuration label End of Configuration ...

Page 7: ...till active after the data is transmitted but the successive transmission of the same bar code is not allowed when the trigger switch is pressed again Trigger mode Auto scan mode 4 2 Good read beeper tone selection You can use this option to set frequency and or duration of the buzzer after successful reading Low Medium High Disable 4 3 Sound duration long 120 ms Medium 50 ms Short 20 ms Very shor...

Page 8: ...e 39 Disable Codabar Enable Codabar Disable UPC EAN JAN Enable UPC EAN JAN Disable ITF 2 of 5 Enable ITF 2 of 5 Disable Chinese Post Code Enable Chinese Post Code Disable Code 128 Enable Code 128 Disable Code 93 Enable Code 93 Disable EAN 128 Enable EAN 128 Disable MSI Enable MSI Disable Baracoda 2004 Page 7 22 ...

Page 9: ...BC BL BLR2604 Programming Guide IATA Enable IATA Disable INDUSTRY 25 Enable INDUSTRY 25 Disable Italian Pharmacy Enable Italian Pharmacy Disable End of Configuration Baracoda 2004 Page 8 22 ...

Page 10: ...GIT Calculate and Transmit Calculate but not Transmit No CONCATENATION Enable Disable IInterleaved 2 of 5 parameters setting Examples Felting length 4 to 8 digits LENTGTH Scan Start of configuration È Min È 0 È 4 È set max È 0 È 8 È set È End of configuration MAX Min Set CHECK DIGIT No Calculate and Transmit Calculate but not Transmit End of Configuration Baracoda 2004 Page 9 22 ...

Page 11: ...t of configuration È Min È 0 È 4 È set max È 0 È 8 È set È End of configuration CHECK DIGIT NO Calculate and Transmit Calculate but not Transmit Codabar Monarch parameters setting START STOP CHARACTER TRANSMISSION No A B C D DC1 DC4 a t b n c d e CONCATENATION Enable Disable End of Configuration Baracoda 2004 Page 10 22 ...

Page 12: ...onfiguration UPC EAN JAN parameters setting FORMAT All EAN 8 or EAN 13 UPC A and EAN 13 UPC A and UPC E UPC A UPC E EAN 13 EAN 8 ADDENDUM NO 5 Characters 2 Characters 2 or 5 Characters FORCE UPC E TO UPC A FORMAT Yes No Baracoda 2004 Page 11 22 ...

Page 13: ... Programming Guide FORCE UPC A TO EAN 13 FORMAT Yes No TRANSMIT UPC A LEADING CHARACTER Yes No TRANSMIT UPC A CHECK DIGIT Yes No TRANSMIT UPC E LEADING CHARACTER Yes No End of Configuration Baracoda 2004 Page 12 22 ...

Page 14: ... Yes No TRANSMIT EAN 8 CHECK DIGIT Yes No Code 128 parameters setting FNC 2 CONCATENATION Enable Disable CHECK DIGIT No Calculate but not Transmit Calculate and Transmit UCC EAN128 parameters setting The character FNC1 can be transmitted or not using these codes FNC1 Character Transmitted FNC1 not Transmitted End of Configuration Baracoda 2004 Page 13 22 ...

Page 15: ...in È 0 È 4 È set max È 0 È 8 È set È End of configuration MAX Min Set Msi Plessy setting Scan Start of configuration È Min È 0 È 4 È set max È 0 È 8 È set È End of configuration MAX Min Set Double Check digit Calculate but not Transmitted No Calculate but only first one Transmitted Calculated and both Transmitted End of Configuration Baracoda 2004 Page 14 22 ...

Page 16: ...alian pharmacy parameters setting TRANSMIT A CHARACTER Yes No Barcode length setting CODE 39 LENGTH SETTING MAX MIN CODE 93 LENGTH SETTING MAX MIN CODE 128 LENGTH SETTING MAX MIN CODABAR LENGTH SETTING MAX MIN SET End of Configuration Baracoda 2004 Page 15 22 ...

Page 17: ...g Guide Start of Configuration ISBN ISSN conversion The function convents the UPC EAN codes appearing on books and magazine not ISBN ISSN format ACTIVE ISBN ISSN INACTIVE ISBN ISSN End of Configuration Baracoda 2004 Page 16 22 ...

Page 18: ...nable full ASCII code 39 option before you start 3 Read the Set label to set your choice into memory 6 2 Barcode identifier code selection The scanners can transmit max 2 digit barcode identifier code for different types of barcodes Use the labels to choose transmit or not transmit predefined barcode identifier code ID s are listed on section 1 Enable Disable 6 3 Barcode identifier code setting Ea...

Page 19: ...BC BL BLR2604 Programming Guide Code 93 MSI INDUSTRY 25 IATA Set End of Configuration Baracoda 2004 Page 18 22 ...

Page 20: ...ation NUL ENQ Up SOH Ins ACK Down STX Del BEL Left ETX Home BS Backspace EOT End HT TAB LF Enter num DLE 5 num VT Right DC1 F1 FF PgUp DC2 F2 CR Enter DC3 F3 SO PgDn DC4 F4 SI shift L NAK F5 SYN F6 GS ESC ETB F7 RS Ctl L CAN F8 US Alt L EM F9 SP SUB F10 ESC F11 Baracoda 2004 Page 19 22 ...

Page 21: ...BC BL BLR2604 Programming Guide FS F12 0 1 2 3 4 5 6 7 8 9 A B I C J D K Baracoda 2004 Page 20 22 ...

Page 22: ...BC BL BLR2604 Programming Guide E L F M G N H O P W Q X R Y S Z T U V e _ f g a h b i c j d k l s m t Baracoda 2004 Page 21 22 ...

Page 23: ...BC BL BLR2604 Programming Guide n u o v p w q x r y z DEL End of Configuration Baracoda 2004 Page 22 22 ...

Reviews: