ToughRunners / ScanWear – Communication Protocol v1.2
- 41 -
Data Capture
for Workforce
in Motion
OPEAN2
Description
Default
b0
UPCE check digit not transmitted
0
b1
UPCE conversion enabled
0
b2
0: transmit UPCE as UPCA
1: transmit UPCE as EAN13
0
b3
0: transmit UPCA as EAN13
1: transmit UPCA as UPCA
1
b4
Reserved (do not modify)
0
b5
UPCE number system not transmitted
0
b6
Reserved (do not modify)
0
b7
EAN13check digit not transmitted
0
Code93 parameters :
OPC93
Description
Default
Reserved (do not modify)
0
EAN128 parameters :
FNC1
Description
Default
b0-b6
ASCII (0 à 127) GS replacment character
0x1D
b7
FNC1 separator character transmitted
0
RSS 14 (GS1 Databar) parameters :
RSS14
Description
Default
b0
RSS14 validation
1
b1
AIM Prefix « ]e0 » validation
1
b2
AIM Prefix « ]C1 » validation (prioritary over b1)
0
b3
Application indentifier AI=(01) validation
1
b4
Checksum modulo 10 validation
1
b5
Linear decoding of composite 2D barcodes allowed
1
b6
Not used
0
b7
Not used
0
RSS Ltd (GS1 Databar Ltd) parameters :
RSS Ltd
Description
Default
b0
RSS Ltd validation
1
b1
AIM Prefix « ]e0 » validation
1
b2
AIM Prefix « ]C1 » validation (prioritary over b1)
0
b3
Application indentifier AI=(01) validation
1
b4
Checksum modulo 10 validation
1
b5
Linear decoding of composite 2D barcodes allowed
1
b6
Not used
0
b7
Not used
0