ToughRunners / ScanWear – Communication Protocol v1.2
- 10 -
Data Capture
for Workforce
in Motion
3.4. Restore default settings
Command ID
0x0F
Description
Restore factory default settings (reboots scanner)
Length
1
payload
A = 0
Response
none
3.5. MMI settings
Command ID
0x40
Description
Get vibrator
Length
0
payload
none
Response
ABC
where :
A = Vibration duration on BAD READ event
B = Vibration duration on BARCODE LOST event
C = Vibration duration on NACK event
Durations in 1/10 sec
Default settings:
0x0A 0x0A 0x0A
Command ID
0x41
Description
Set vibrator
Length
3
payload
ABC
where :
A = Vibration duration on BAD READ event