2501
Soft start switch
ON/OFF
OFF
2502
Soft start speed
200-1500
400
2503
Stitch numbers for soft start
1-99
1
2.6 Machine switch setting
No.
Items
Range
Default
Description
2601
Manual switch A setting
0-6
5
0: OFF
1: half stitch
2: one stitch
3: continuous half stitch
4: continuous one stitch
5: Back-tacking when machine stop or pause
6: Tight seam function
2602
Manual switch B setting
0-6
3
0: OFF
1: half stitch
2: one stitch
3: continuous half stitch
4: continuous one stitch
5: Back-tacking when machine stop or pause
6: Tight seam function
2603
Manual switch C setting
0-6
0
0: OFF
1: half stitch
2: one stitch
3: continuous half stitch
4: continuous one stitch
5: Back-tacking when machine stop or pause
6: Tight seam function
2604
Manual switch D setting
0-6
0
0: OFF
1: half stitch
2: one stitch
3: continuous half stitch
4: continuous one stitch
5: Back-tacking when machine stop or pause
6: Tight seam function
2.7 Clamping & tension setting
No.
Items
Range
Default
Description
Parameter
2701
Tension strength setting
1-5
3
P103
2702
With or without tension
while foot lifting action
ON/OFF
OFF
P35
2703
Wiping / clamping
strength setting
0-11
6
0: OFF
1: Wiping function
2
~
11: Clamping function, the higher the
value, the stronger the action.
P37
2704
Tension function switch
ON/OFF
ON
P36
2705
The foot lift height of
thread tension release
start action when
knee-control foot lift
0-300
115
P25
2.8 Interface display
No.
Items
Range
Default
Description
2801
Brightness
5-100
80
The larger the value, the higher the brightness.
7