background image

2

1-10

"4" represents the total number of segments of
the pattern. If you click, you can select the total
number of segments.
"3" represents the segment No. of the pattern.
As shown in the figure, there are 4 patterns in the
3rd pattern. The figure is the data of the 3rd
segment.

3

1-99

1

"1" represents the stitch numbers of the pattern.
As shown in the figure, the number of stitches in
the 3rd segment of the 3rd pattern is 1.

4

1-9

5

"1" represents the repeat times of the pattern. As
shown in the figure, the repeat times for the 3rd
segment of the 3rd pattern is 1.

5

0-5.0

4.8

"1.0" represents the stitches length of this pattern.
As shown in the figure, the stitches length of the
3rd segment of the 3rd pattern is 1.0 mm.

1.3 Constant Stitch Sewing Interface Description

No.

Items

Range

Default

Description

1

1-15

4

"4" represents the number of constant stitch
sewing mode. As shown in the figure, it
represents 4th constant stitch sewing mode.

2

1-4

"4" represents the total number of segments of
the constant stitch sewing mode. If clicked, the
total number of segments can be selected.
"1" represents the segment No. of constant stitch
sewing.
As shown in the figure, it represents the data of
the 1st segment of the 4 segments.

3

0-99

12

"1" represents the number of stitches in this
segment. As shown in the figure, the number of
stitches in the 1st segment of the 4 segments is 1.

4

Summary of Contents for GT-288C-D4

Page 1: ... needle c Raising the machine head d Repairing or doing any mechanical adjustment e Machines idling 14 Repairs and high level maintenance work should only be carried out by electronic technicians with appropriate training 15 All the spare parts for repair must be provided or approved by the manufacturer 16 Don t use any objects or force to hit or ram the product Guarantee Time Warranty period of t...

Page 2: ...the lock screen and unlock Mode selection If click shift to free sewing continuous back seam mode constant stitch sewing and pattern seam mode Start back tacking If click executions starting back seam B segment execution starting back seam A B segment 1 time or execution starting back seam A B segment 2 times If long press switch to back tacking setting End back tacking If click execution terminat...

Page 3: ...r cancelled back tacking pattern function Slow launch setting If click set used or cancelled slow launch function Advanced parameter settings If double click enter the advanced parameter setting interface Trimming count display The trimming count value is displayed If double click the count is cleared Sewing speed display The sewing speed of the current mode is displayed If click select this data ...

Page 4: ...nts the stitches length of this pattern As shown in the figure the stitches length of the 3rd segment of the 3rd pattern is 1 0 mm 1 3 Constant Stitch Sewing Interface Description No Items Range Default Description 1 1 15 4 4 represents the number of constant stitch sewing mode As shown in the figure it represents 4th constant stitch sewing mode 2 1 4 4 represents the total number of segments of t...

Page 5: ...e corresponding settings interface No Setting 1 Main shaft motor setting 2 Tight seam function setting 3 Back tacking setting 4 Counter setting 5 Soft start setting 6 Machine switch setting 7 Clamp tension setting 8 Interface display 9 Layer seam setting 10 Clamp function without any thrum 2 1 Main shaft motor setting No Items Range Default Description 2101 Needles goes up automatically as power t...

Page 6: ...n execute end back tacking sewing function selection OFF ON ON 2305 Star back tacking mode selection OFF ON ON 2306 Mode selection at the end of start back tacking OFF ON ON 2 4 Counter setting No Items Range Default Description 2401 Counter selection 0 2 1 0 Counter does not count 1 Count up sewing counter Each time the thread is cut the count is increased by 1 the current value and the set value...

Page 7: ... 5 Back tacking when machine stop or pause 6 Tight seam function 2604 Manual switch D setting 0 6 0 0 OFF 1 half stitch 2 one stitch 3 continuous half stitch 4 continuous one stitch 5 Back tacking when machine stop or pause 6 Tight seam function 2 7 Clamping tension setting No Items Range Default Description Parameter 2701 Tension strength setting 1 5 3 P103 2702 With or without tension while foot...

Page 8: ...ng 6 Safety protection setting 7 Stitch length setting of stepping back tacking 8 Testing mode 9 State information 10 Main shaft motor setting 11 Clamp function without any thrum 12 Layer seam setting 13 Other settings 3 1 Trimming function setting No Items Range Default Description 3101 Trimming step return speed 20 400 150 3102 Trimming first section speed 20 400 200 3103 Trimming second section...

Page 9: ...dy current 1 8 6 P150 3307 Presser foot motor maximum current 1 12 10 P152 3308 Electronic knee control device the lowest presser foot lift height 0 200 20 P135 3309 Electronic knee control device the highest presser foot lift height 0 200 160 P126 3310 The highest of presser foot lift highness limit 0 300 150 P172 3 4 Tension setting No Items Range Default Description 3401 Tension starting angle ...

Page 10: ...motor zero point correction 100 100 50 3702 Normal stitch length 0 5 0 3 0 3703 Stitch length reference value setting 3704 Tacking stitch length compensation 0 100 50 3705 Back tacking stitch length compensation 0 100 58 3706 Back tacking stitch compensation 0 200 167 3707 Back tacking step motor steady current 1 12 6 3708 Back tacking step motor maximum current 1 12 12 3709 Manual close stitches ...

Page 11: ...nning Direction Periodic Time m No limit at time 0 1 3500 30 10 CCW 0 2 0 0 0 CCW 0 3 0 0 0 CCW 0 4 0 0 0 CCW 0 5 0 0 0 CCW 0 3 9 State information No Items Range Default Description 22901 Version number 22902 Motor speed display Display current motor speed 22903 Needle position angle value Display the current motor angle of the machine 22904 Pedal AD value Display the current AD value of the peda...

Page 12: ... way 1 45 16 31012 Stopping strength after trimming 1 50 20 31013 Up down needle position distance value 15 359 175 In the quick setting interface of the needle position for the upper and lower stops when the upper positioning value is saved the lower positioning value will be automatically calculated based on the upper and lower positioning distance values 31014 Main shaft motor rotation direct s...

Page 13: ...yer seam stitch length limit 0 5 0 4 0 3 13 Other setting No Items Range Default Description Parameter 31301 Type selection 1 50 37 P70 4 Error Code List Error Code Problem Measure E01 Over voltage Turn off the system power and check whether the power supply voltage is correct Or whether it exceeds the specified rated voltage E02 Low voltage Turn off the system power and check whether the power su...

Page 14: ...e To get it right and turn on If there are still errors please replace the control box and call for customer service E10 Solenoid over current protection Turn off the system power supply please check the solenoid solenoid valve connector or solenoid solenoid valve is broken or not E14 Encoder signal error Turn off the system power supply please check motor encoder connector if loose or fall off re...

Reviews: