BaoLai Medical BCL-A Instruction Manual Download Page 5

4.

Technical specifications

4.1 

AC24V  50Hz.

Power input

4.2 

10VA.

Input power

4

.

26

×

221mm

.

Dimensions

4

.

0.18kg

.

Net weight

4

.

5

 

Components: details in packing list.

4

.

6

 

:

LED light performance

4

.

6.1 LED power: 5W.

4

.

6

.

2

 

:440nm~480nm.

Wave length

4

.

6

.

3

 

 :

 I.

Category

4

.

6

.

4

 

:

Light intensity

a

:

1000mW

/

cm

²~

1300mW

/

cm

².

Low power

2

2

b

:1600mW

/cm ~1800m

W

/cm .

High power

2

4

.

6

.

5

 

 56mm .

Optical active area

  .  

:

4 7 Working condition

. .  

:+5℃ +

0

.

4 7 1

~ 3

Environment temperature

. .  

:0~80%.

4 7 2 Relative humidity

. .  

:70KPa~106KPa.

4 7 3 Atmosphere pressure

.  

:

4 8 Design safety category

. .  

I

ndirect running

4 8 1 Running mode

. .  

4 8 2

I.

Protection type against electrical shock:class 

. .  

4 8 3 Protection against electrical shock:type B

.

. .  

4 8 4 Protection against harmful ingress of water or
particular matter:ordinary equipment (IPX0).

. .  

4 8 5 Safety in the presence of flammable anesthetic
mixture with air,oxygen or nitrous oxide:Non AP/APG type 
equipment

.

5

.

Components

5

.

1

 

No spare parts, accessories,consumables.

5

.

2

 

More details about product and accompanying 

documents in the packing list.

3

Summary of Contents for BCL-A

Page 1: ...100 155mm 80g BCL A PA BCL A M E 1 A1 BCL A Built in LED curing light Instruction Manual 20190924...

Page 2: ...I...

Page 3: ...1 The light emittel may be harmful to the eyes Do not stare at the light source...

Page 4: ......

Page 5: ...Environment temperature 0 80 4 7 2 Relative humidity 70KPa 106KPa 4 7 3 Atmosphere pressure 4 8 Design safety category Indirect running 4 8 1 Running mode 4 8 2 I Protection type against electrical sh...

Page 6: ...ap between lamp cap and main unit When the metal clamping ring there is voice feedback flicks 7 Cleaning and sterilization 7 1 Cleaning 7 1 1Pull out of the lamp cap from BCL A curing light wipe it wi...

Page 7: ...unit shines blue light and starts countdown 8 8 It can be stopped working at any time by short pressing P button while operating The next working cyble should be started after a working 8 9 cycle ends...

Page 8: ...of GB9706 1 standards 9 6 Using product must conform to the related operation rules issued by health sector and the related laws requirements It can be used by trained doctors or technicians only 9 7...

Page 9: ...or us LED ageing There is residual foreign matter at the front end of lamp cap BCL A curing light without electric power Curing light stops working for several minutes and it will return to normal BCL...

Page 10: ...ponsible for the maintenance base on the warranty card Please refer the warranty scope and period from warranty card 16 EMC Declaration of conformity Notes 1 Maybe it will cause electromagnetic compat...

Page 11: ...operation when there is light Set time by T button and choose high intensity or low intensity by M button when there is no light Light output Guidance and manufacturer s declaration electromagnetic e...

Page 12: ...ty The model BCL A is intended for use in the electromagnetic environment speci ed beliw The customer or the user of the model BCL A shouid assure that lt is used in such an environment 16 5 Guidance...

Page 13: ...PORT IMMUNITY to RF wireless communication equipment Refer to table 9 of IEC 60601 1 2 2014 3 Vrms 150 kHz to 80MHz 6 Vrms in ISM and amateur radio bands 3 V m 80 MHZ to 2 5 GHz 10 V m 80 MHZ to 2 7...

Page 14: ...12 BCL A BCL A BCL A...

Page 15: ...13 BCL A BCL A BCL A BCL A...

Page 16: ...PA BCL A M E 1 Rev A1...