Initial parameters setup (User Program Setup)

 BC6HP will be operated with the default value of the essential user settings when it is 
connected to a  12V DC input power source for the first time. The screen displays the 
following information in sequence and the user can change the value of parameter on 
each screen.
 When you are willing to alter the parameter value in the program, press ‘ENTER/START’ 
button to make it blinking, then change the value using ‘INC’ or ‘DEC’ button. The value 
will be stored by pressing ‘ENTER/START’ button once.

BC6HP recognises the cell count of Lithium battery 
automatically at the beginning of process to avoid from 
erroneous setting by user. But deeply discharged battery 
can be perceived incorrectly. To prevent the error, you 
can set the time term to verify the cell count by the 
processor. Normally, 10 minutes are enough to perceive 
the cell count correctly. For the battery of larger capacity, 
you may extend the time term. But if you set the time 
term too long for the battery of smaller capacity, the 
charge or discharge process can be finished within the 
time term with the erroneous cell count. This may cause 
the fatal result. If the processor recognizes the cell count 
incorrectly at the beginning of charge or discharge 
process, you may extend the time. Otherwise, you had 
better use with the default value.

Display

LiPo/LiIo/LiFe
CHK Time  10min

Display

NiMH Sensitivity
D.Peak    Default

INC

DEC

 This shows the trigger voltage for automatic charge 
termination of NiMH and NiCd battery. If the trigger 
voltage is set higher, there is a danger of overcharging 
the battery; if it is set lower, there is a possibility of 
premature termination. Please refer the technical 
specification of the battery.
(Disable, Delicate, Default, 5mV~20mV/cell)
   

Disable

; The charger would not detect Delta-peak 

voltage for termination. To terminate charging process, 
the charger will check the parameters set up at other 
safety parameters like max. capacity, safety timer or 
safety temperature. If any one has been reached at its 
limit, the charging process will be terminated. (for NiMH 
only)
  

Delicate

; The charger will detect a very small variation 

at delta-peak voltage. Some NiMH batteries which 
shows small voltage-drop at peak need to be use this 
option.

-

+

DEC INC

INC

DEC

-

+

DEC

INC

Display

NiCd Sensitivity
D.Peak    Default

-

+

DEC

INC

                                            

 

 

- 7 -

   

                                        

+

-

+

-

+

-

+

-

+

-

+

-

-

+

-

+

-

-

+

-

+

-

+

-

+

-

!

!

!

INC

DEC

Summary of Contents for e-STATION BC6HP

Page 1: ...ssor controlled high performance rapid charger discharger with integrated balancer 250watts of charging power USB PC link and firmware upgrade Temperature sensor Charge current up to 10A discharge cur...

Page 2: ...charge Lithium battery for special purposes Fast charge reduces the charging time of Lithium battery and Storage mode controls the final voltage of the battery to be suit for long time storage Maximu...

Page 3: ...its voltage always being monitored If it drops below the lower limit the process will be ended automatically Data store load For users convenience it can store maximum 10 data of different batteries Y...

Page 4: ...ay be very hot and can cause a physical damage on your finger or body Be sure to understand the information of the battery to be charged or discharged accurately If the program is set up incorrectly t...

Page 5: ...ng the charge process To avoid short circuits between the charge lead always connect the charge cable to the unit first and only then to the battery to be charged or discharged Reverse the sequence wh...

Page 6: ...TYPE STOP TYPE STOP Capacity Cut off INC INC DEC DEC NiMH NiCd Pb Trickle charge Key Beep Buzzer 6 DEC DEC INC INC DEC DEC INC INC DEC DEC INC INC DEC DEC INC INC DEC DEC INC INC DEC DEC INC INC DEC D...

Page 7: ...nished within the time term with the erroneous cell count This may cause the fatal result If the processor recognizes the cell count incorrectly at the beginning of charge or discharge process you may...

Page 8: ...isplay NiMH NiCd Pb Trickle 100mA INC DEC DEC INC You can set the trickle charge mode on or off If it is on the charger will automatically supply the trickle charge current to achieve the full charge...

Page 9: ...pe of batteries by number that represents the individual parameters They can be called back for the process of charging or discharging without setting up the program again Select the data number using...

Page 10: ...s the number of cells found by the charger and S is the number of cells selected by you at the previous screen If both numbers are identical you can start charging by press ENTER START button If not p...

Page 11: ...value on the right side of second line sets the voltage of the battery pack After setting the current and voltage press ENTER START button for more than 3 seconds to start the process Charge current...

Page 12: ...10 at end of CV term The charging capacity may be a bit smaller than normal charging but the process time will be reduced This is for charging or discharging Lithium battery not to be used for the ti...

Page 13: ...uld be connected to the individual port of the charger If the voltage of any one or more cells varies abnormally during discharge BC6HP terminates the process forcibly with the error message If this h...

Page 14: ...mode to M or A using INC or DEC button Press ENTER START button to alter the charge current Change the current value using INC or DEC button Press ENTER START button for more than 3 seconds to start c...

Page 15: ...r NiMH 2 0A 7 42V D C 022 45 00890 ENTER START TYPE STOP DEC INC DEC INC battery voltage discharge or charge current discharged or charged capacity elapsed time battery type 15 Display NiMH 0 REFLEX 3...

Page 16: ...ranges from 0 1 to 10 0A and the voltage should be matched with the battery being charged ENTER the charge process by pressing ENTER START button for more than 3 seconds The screen displays the state...

Page 17: ...d when using the thermal probe The present voltage of input DC power Various information during the process DEC Display Capacity Cut Off ON 5000mAh Display Safety Timer ON 200min Display Temp Cut Off...

Page 18: ...tive and monitoring the system to verify functions and the state of its electronics In any case of occurring error the screen displays the cause of error that is self explanatory with audible sound Th...

Page 19: ...ry can deliver 60 amps of current for one hour 60Ax1hr 60Ah Nominal voltage V The nominal voltage of the battery pack can be determined as follows NiCd or NiMH multiply the total number of cells in th...

Page 20: ...C149 Please read the instructions come with the board for the maximum safety Li Po 1S Li Po 2S Li Po 3S 4 cell 3 cell 2 cell 1 cell 5 cell 6 cell Individual bal port Li Po 1S Li Po 2S Li Po 3S BC6HP O...

Page 21: ...m Warranty and service We warrant this product for a period of one year 12 months from the date of purchase The guarantee applies only to such material or operational defects which are present at the...

Reviews: