4 Select Sensing Mode
By default, the sensing mode is set to Transparent. To select either Film or Opaque mode, follow these steps.
1. Access the Select Sensing Mode.
Method
Action
Result
Push Button
Click the button 5-times.
Select Sensing Mode
enabled (Amber LED
flashes at 1 Hz).
Remote Line
Pulse the remote line 5-times.
T
T
T
T
T
T
T
T
T
2. Select the desired sensing mode.
Method
Sensing
Mode
Action
Result
Push Button
Transparent
Click the button 1-time.
The selected
sensing mode is
enabled.
Film
Click the button 2-times.
Opaque
Click the button 3-times.
IO-Link
Transparent
Set BDC1 Mode using IO-Link.
Film
Set BDC1 Mode using IO-Link.
Opaque
Set BDC1 Mode using IO-Link.
Remote Line
Transparent
Pulse the remote line 1-time.
T
Film
Pulse the remote line 2-times.
T
T
T
Opaque
Pulse the remote line 3-times.
T
T
T
T
T
4.1 Transparent Mode Set
Use Transparent mode for low contrast applications where the object
is not present during the teach process. Transparent mode is the
default sensing mode and is best for most clear object detection
applications.
Example Applications For Offset Percentages
8%
Recommended for very low contrast applications with stable
environmental conditions.
16%
Recommended for most clear object detection applications in
typical machine industrial environments.
32%
Recommended for high contrast detections such as brown or
green bottles, or opaque objects. This setting tolerates
environmental challenges such as vibrations and dust build-up.
Darkest
Most Light
Output ON
Output OFF
Condition
presented
Sensor position’s threshold is a
programmable % offset below
the presented condition
Figure 9. Transparent Mode
WORLD-BEAM
®
QS18E Clear Object Detection with IO-Link
www.bannerengineering.com - Tel: 763.544.3164
9