Banner SureCross FlexPower DX80 Series Instruction Manual Download Page 12

THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (IN-
CLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND
WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.
This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL
BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPEN-
SES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY
PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WAR-
RANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.
Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or
liabilities relating to any product previously manufactured by Banner Engineering Corp.

Contact Us

For more information: Contact your local Banner representative or Banner Corporate Offices around the world.

Banner Corporate Head-
quarters
Banner Engineering Corp.
9714 Tenth Ave. North
Mpls., MN 55441
Tel: 763-544-3164

www.bannerengineering.com
sensors@bannerengineer-
ing.com

Asia — China 
Banner Engineering China
Shanghai Rep Office
Rm. G/H/I, 28th Flr.
Cross Region Plaza
No. 899, Lingling Road
Shanghai 200030 CHINA
Tel: 86-21-54894500, Fax:
86-21-54894511

www.bannerengineer-
ing.com.cn
sensors@bannerengineer-
ing.com.cn

Europe 
Banner Engineering Europe
Park Lane
Culliganlaan 2F
Diegem B-1831
BELGIUM
Tel: 32-2 456 07 80, Fax:
32-2 456 07 89

www.bannereurope.com
[email protected]

Asia — Taiwan 
Banner Engineering Taiwan 
8F-2, No. 308
Section 1, Neihu Road
Taipei 114
Tel: 886-2-8751-9966, Fax:
886-2-8751-2966

www.bannerengineer-
ing.com.tw
info@bannerengineer-
ing.com.tw

Latin America
Contact Banner Engineering
Corp. (US) or e-mail:
Mexico:

mexico@banneren-

gineering.com

Brazil: 

brasil@bannerengin-

eering.com

Asia — Japan 
Banner Engineering Japan
Cent-Urban Building 305
3-23-15, Nishi-Nakajima
Yodogawa-Ku, Osaka
532-0011 JAPAN
Tel: 81-6-6309-0411, Fax:
81-6-6309-0416

www.bannerengineering.co.jp
mail@bannerengineer-
ing.co.jp

Asia — India 
Banner Engineering India 
Pune Head Quarters
Office No. 1001
Sai Capital Opp. ICC
Senapati Bapat Road
Pune 411016 INDIA
Tel: 91-20-66405624, Fax:
91-20-66405623

www.bannerengineering.co.in
[email protected]

 

 

SureCross DX80 FlexPower Thermocouple Node

 

 

 

Summary of Contents for SureCross FlexPower DX80 Series

Page 1: ...for use in Class I Division 2 Group A B C D Zone 2 Group IIC Hazardous Locations when properly installed in accordance with the National Electrical Code the Canadian Electrical Code LCIE ATEX or appli...

Page 2: ...and controls the I O configuration for the network A radio network contains only one Gateway but can contain many Nodes Similar to how a gateway device on a wired network acts as a portal between net...

Page 3: ...way DX85 10 to 30V dc Powered Nodes Battery Powered Nodes V 10 to 30V dc 10 to 30V dc Tx RS485 D1 B V dc common GND dc common GND dc common GND Rx RS485 D0 A B 3 6 to 5 5V dc Connecting dc power to th...

Page 4: ...to 5 5V dc for battery powered models only Wiring Diagrams for Discrete Inputs Connecting dc power to the communication pins will cause permanent damage For the DX8x C models PWR in the wiring diagram...

Page 5: ...to 3 272 F 100 to 1 800 C Type C 32 to 4 208 F 0 to 2 320 C Type E 58 to 1 832 F 50 to 1 000 C Type J 292 to 1 382 F 180 to 750 C Type K 292 to 2 282 F 180 to 1 250 C Type L 328 to 1 652 F 200 to 900...

Page 6: ...gh resolution mode the temperature Modbus register value 20 In low resolution mode the temperature is Modbus register value 2 Temperature values are stored as signed values in the Modbus register A 0...

Page 7: ...ess mode ON Temp Fahrenheit OFF Temp Celsius ON High resolution 0 1 degree OFF Low resolution 1 degree ON Discrete sinking inputs OFF Discrete sourcing inputs ON Thermocouple J Type OFF OFF OFF OFF Th...

Page 8: ...its Use the DIP switch to specify if the temperature is stored in degrees Fahrenheit or Celsius The default position is OFF setting the temperature to Fahrenheit For Celsius measurements set this swit...

Page 9: ...47 ETSI EN In accordance with EN 300 328 V1 7 1 2006 05 IC 7044A DX8024 Spread Spectrum Technology FHSS Frequency Hopping Spread Spectrum Antenna Connection Ext Reverse Polarity SMA 50 Ohms Max Tighte...

Page 10: ...to 80 C Operating Temperature 40 to 85 C Electronics 20 to 80 C LCD Operating Humidity 95 max relative non condens ing Radiated Immunity 10 V m 80 2700 MHz EN61000 6 2 Shock and Vibration IEC 68 2 6 a...

Page 11: ...ions installed without surge suppressors invalidate the manufacturer s warranty Always keep the ground wire as short as possible and make all ground connections to a single point ground system to ensu...

Page 12: ...Banner Engineering Corp 9714 Tenth Ave North Mpls MN 55441 Tel 763 544 3164 www bannerengineering com sensors bannerengineer ing com Asia China Banner Engineering China Shanghai Rep Office Rm G H I 2...

Reviews: