Banner SureCross FlexPower DX80 Series Instruction Manual Download Page 11

1

Plug, 1/2" NPT

1

Nylon gland fitting, 1/2" NPT

Mounting Hardware Kit

BWA-HW-001

4

Screw, M5-0.8 x 25mm, SS

4

Screw, M5-0.8 x 16mm, SS

4

Hex nut, M5-0.8mm, SS

4

Bolt, #8-32 x 3/4", SS

PTFE Tape

BWA-HW-003

1

Antenna **

BWA-9O2-C, or
BWA-2O2-C

1

Antenna, 902-928 MHz, 2 dBd Omni, Rubber Swivel RP-SMA
Male, or Antenna, 2.4 GHz, 2 dBd Omni, Rubber Swivel RP-
SMA Male

SureCross Literature CD

79685

1

SureCross Quick Start Guide

128185

1

(Ships with Gateways)

Cable *

MQDC1-506

1

Cable, 5-Euro (single ended), Straight, 2m

IP20 Screw Terminal Headers (2
pack) ***

BWA-HW-011

1

* Not included with IP20 DX80...C models.
** Internal antenna devices do not ship with this antenna.
*** Not included with IP67 DX80 models.

Warnings

The manufacturer does not take responsibility for the violation of any warning listed in this document.
Make no modifications to this product. Any modifications to this product not expressly approved by Banner Engineering could void the
user’s authority to operate the product. Contact the Factory for more information.
All specifications published in this document are subject to change. Banner reserves the right to modify the specifications of prod-
ucts without notice. Banner Engineering reserves the right to update or change documentation at any time. For the most recent version of
any documentation, refer to our website: 

www.bannerengineering.com

©

 2006-2010 Banner Engineering Corp. All rights reserved.

Antenna Installation

Always install and properly ground a qualified surge suppressor when installing a remote antenna system. Remote antenna configura-
tions installed without surge suppressors invalidate the manufacturer's warranty.
Always keep the ground wire as short as possible and make all ground connections to a single-point ground system to ensure no ground
loops are created. No surge suppressor can absorb all lightning strikes. Do not touch the SureCross

 device or any equipment connec-

ted to the SureCross device during a thunderstorm.

Exporting SureCross Radios

It is our intent to fully comply with all national and regional regulations regarding radio frequency emissions. Customers who want to re-
export this product to a country other than that to which it was sold must ensure the device is approved in the destination
country.
 A list of approved countries appears in the Agency Certifications section of the product manual. The SureCross wireless prod-
ucts were certified for use in these countries using the antenna that ships with the product. When using other antennas, verify you are not
exceeding the transmit power levels allowed by local governing agencies. Consult with Banner Engineering if the destination country is
not on this list.

Banner Engineering Corp Limited Warranty

Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of
shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned
to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse,
abuse, or the improper application or installation of the Banner product.

SureCross DX80 FlexPower Thermocouple Node

 

 

P/N 131297 rev. I

www.bannerengineering.com - tel: 763-544-3164

11

Summary of Contents for SureCross FlexPower DX80 Series

Page 1: ...for use in Class I Division 2 Group A B C D Zone 2 Group IIC Hazardous Locations when properly installed in accordance with the National Electrical Code the Canadian Electrical Code LCIE ATEX or appli...

Page 2: ...and controls the I O configuration for the network A radio network contains only one Gateway but can contain many Nodes Similar to how a gateway device on a wired network acts as a portal between net...

Page 3: ...way DX85 10 to 30V dc Powered Nodes Battery Powered Nodes V 10 to 30V dc 10 to 30V dc Tx RS485 D1 B V dc common GND dc common GND dc common GND Rx RS485 D0 A B 3 6 to 5 5V dc Connecting dc power to th...

Page 4: ...to 5 5V dc for battery powered models only Wiring Diagrams for Discrete Inputs Connecting dc power to the communication pins will cause permanent damage For the DX8x C models PWR in the wiring diagram...

Page 5: ...to 3 272 F 100 to 1 800 C Type C 32 to 4 208 F 0 to 2 320 C Type E 58 to 1 832 F 50 to 1 000 C Type J 292 to 1 382 F 180 to 750 C Type K 292 to 2 282 F 180 to 1 250 C Type L 328 to 1 652 F 200 to 900...

Page 6: ...gh resolution mode the temperature Modbus register value 20 In low resolution mode the temperature is Modbus register value 2 Temperature values are stored as signed values in the Modbus register A 0...

Page 7: ...ess mode ON Temp Fahrenheit OFF Temp Celsius ON High resolution 0 1 degree OFF Low resolution 1 degree ON Discrete sinking inputs OFF Discrete sourcing inputs ON Thermocouple J Type OFF OFF OFF OFF Th...

Page 8: ...its Use the DIP switch to specify if the temperature is stored in degrees Fahrenheit or Celsius The default position is OFF setting the temperature to Fahrenheit For Celsius measurements set this swit...

Page 9: ...47 ETSI EN In accordance with EN 300 328 V1 7 1 2006 05 IC 7044A DX8024 Spread Spectrum Technology FHSS Frequency Hopping Spread Spectrum Antenna Connection Ext Reverse Polarity SMA 50 Ohms Max Tighte...

Page 10: ...to 80 C Operating Temperature 40 to 85 C Electronics 20 to 80 C LCD Operating Humidity 95 max relative non condens ing Radiated Immunity 10 V m 80 2700 MHz EN61000 6 2 Shock and Vibration IEC 68 2 6 a...

Page 11: ...ions installed without surge suppressors invalidate the manufacturer s warranty Always keep the ground wire as short as possible and make all ground connections to a single point ground system to ensu...

Page 12: ...Banner Engineering Corp 9714 Tenth Ave North Mpls MN 55441 Tel 763 544 3164 www bannerengineering com sensors bannerengineer ing com Asia China Banner Engineering China Shanghai Rep Office Rm G H I 2...

Reviews: