Configurable temperature Node with thermocouple inputs and discrete I/O

Features

IP67 Base
2.4 GHz

IP20 Base
900 MHz

The SureCross

 wireless system is a radio frequency network with integrated I/O that

can operate in most environments while eliminating the need for wiring runs. Systems
are built around a Gateway, which acts as the wireless network master device, and one
or more Nodes.

• Wireless industrial I/O device with up to three configurable thermocouple inputs (de-

faults to J-type), two selectable discrete inputs, and two NMOS discrete outputs

• One thermistor input used for integrated cold junction compensation (CJC)
• FlexPower

 power options allows for +10 to 30V dc, solar, and battery power sour-

ces for low power applications.

• DIP switches for user configuration
• Frequency Hopping Spread Spectrum (FHSS) technology and Time Division Multi-

ple Access (TDMA) control architecture combine to ensure reliable data delivery
within the unlicensed Industrial, Scientific, and Medical (ISM) band

• Transceivers provide bidirectional communication between the Gateway and Node,

including fully acknowledged data transmission

• Lost RF links are detected and relevant outputs set to user-defined conditions
• The DX80...C models are certified for use in Class I, Division 2, Group A, B, C, D;

Zone 2 (Group IIC) Hazardous Locations when properly installed in accordance with
the National Electrical Code, the Canadian Electrical Code, LCIE/ATEX, or applica-
ble local codes/regulations (see Specifications)

For additional information, the most recent version of all documentation, and a complete list of accessories, refer to Banner Engineering's
website, 

www.bannerengineering.com/surecross

.

Models

Model

Frequency

Environmental Rating

I/O

DX80N9X2S2N2T

900 MHz ISM Band

IP67, NEMA 6

Inputs: Three thermocouople, two select-
able discrete, one thermistor input for
CJC
Outputs: Two NMOS sinking discrete

DX80N2X2S2N2T

2.4 GHz ISM Band

DX80N9X2S2N2TC

900 MHz ISM Band IP20, NEMA 1

Class I, Division 2, Group A, B, C, D Haz-
ardous Locations (see Specifications)

DX80N2X2S2N2TC

2.4 GHz ISM Band

Internal antenna models are also available. For more information, contact your local Banner Engineering Corp. representative.

WARNING: Not To Be Used for Personnel Protection
Never use this product as a sensing device for personnel protection. Doing so could lead to serious injury
or death. This product does NOT include the self-checking redundant circuitry necessary to allow its use in
personnel safety applications. A sensor failure or malfunction can cause either an energized or de-ener-
gized sensor output condition.

SureCross DX80 FlexPower Thermocouple Node

 

 

P/N 131297 rev. I

8/18/2011

0 131297

3

Summary of Contents for SureCross FlexPower DX80 Series

Page 1: ...for use in Class I Division 2 Group A B C D Zone 2 Group IIC Hazardous Locations when properly installed in accordance with the National Electrical Code the Canadian Electrical Code LCIE ATEX or appli...

Page 2: ...and controls the I O configuration for the network A radio network contains only one Gateway but can contain many Nodes Similar to how a gateway device on a wired network acts as a portal between net...

Page 3: ...way DX85 10 to 30V dc Powered Nodes Battery Powered Nodes V 10 to 30V dc 10 to 30V dc Tx RS485 D1 B V dc common GND dc common GND dc common GND Rx RS485 D0 A B 3 6 to 5 5V dc Connecting dc power to th...

Page 4: ...to 5 5V dc for battery powered models only Wiring Diagrams for Discrete Inputs Connecting dc power to the communication pins will cause permanent damage For the DX8x C models PWR in the wiring diagram...

Page 5: ...to 3 272 F 100 to 1 800 C Type C 32 to 4 208 F 0 to 2 320 C Type E 58 to 1 832 F 50 to 1 000 C Type J 292 to 1 382 F 180 to 750 C Type K 292 to 2 282 F 180 to 1 250 C Type L 328 to 1 652 F 200 to 900...

Page 6: ...gh resolution mode the temperature Modbus register value 20 In low resolution mode the temperature is Modbus register value 2 Temperature values are stored as signed values in the Modbus register A 0...

Page 7: ...ess mode ON Temp Fahrenheit OFF Temp Celsius ON High resolution 0 1 degree OFF Low resolution 1 degree ON Discrete sinking inputs OFF Discrete sourcing inputs ON Thermocouple J Type OFF OFF OFF OFF Th...

Page 8: ...its Use the DIP switch to specify if the temperature is stored in degrees Fahrenheit or Celsius The default position is OFF setting the temperature to Fahrenheit For Celsius measurements set this swit...

Page 9: ...47 ETSI EN In accordance with EN 300 328 V1 7 1 2006 05 IC 7044A DX8024 Spread Spectrum Technology FHSS Frequency Hopping Spread Spectrum Antenna Connection Ext Reverse Polarity SMA 50 Ohms Max Tighte...

Page 10: ...to 80 C Operating Temperature 40 to 85 C Electronics 20 to 80 C LCD Operating Humidity 95 max relative non condens ing Radiated Immunity 10 V m 80 2700 MHz EN61000 6 2 Shock and Vibration IEC 68 2 6 a...

Page 11: ...ions installed without surge suppressors invalidate the manufacturer s warranty Always keep the ground wire as short as possible and make all ground connections to a single point ground system to ensu...

Page 12: ...Banner Engineering Corp 9714 Tenth Ave North Mpls MN 55441 Tel 763 544 3164 www bannerengineering com sensors bannerengineer ing com Asia China Banner Engineering China Shanghai Rep Office Rm G H I 2...

Reviews: