background image

Dimensions

All measurements are listed in millimeters, unless noted otherwise.

Figure 6. Dimensions for the R70SR

M30 x 1

M12 x 1

Ø70 mm

[2.76”]

8 mm
[0.32”]

33.3 mm

[1.31”]

20.9 mm

[0.82”]

24.9 mm

[0.98”]

Accessories

5-Pin Threaded M12 Cordsets—Double Ended

Model

Length

Style

Dimensions

Pinout (Male)

Pinout (Female)

MQDEC-501SS

0.31 m (1.02 ft)

Male Straight/

Female Straight

40 Typ.

ø 14.5

M12 x 1

44 Typ.

ø 14.5

M12 x 1

1

4

5

3

2

2

3

4

1

5

MQDEC-503SS

0.91 m (2.99 ft)

1 = Brown

2 = White

3 = Blue

4 = Black

5 = Gray

MQDEC-506SS

1.83 m (6 ft)

MQDEC-512SS

3.66 m (12 ft)

MQDEC-515SS

5 m (16.4 ft)

MQDEC-530SS

9 m (29.5 ft)

MQDEC-550SS

15 m (49.2 ft)

5-Pin Threaded M12 Splitter Cordset with Flat Junction—Double Ended

Model

Trunk (Male)

Branches (Female)

Pinout (Male)

Pinout (Female)

CSB4-M1251M1250

0.3 m (0.98 ft)

Four (no cable)

1

4

5

3

2

2

3

4

1

5

 

 

Sure Cross

®

 R70SR Serial Data Radio

6

www.bannerengineering.com - Tel: + 1 888 373 6767

P/N 224673 Rev. B

Summary of Contents for Sure Cross R70SR Series

Page 1: ...work Connect your serial devices using a serial cable Note the baud rate and parity of your serial devices so that you can use the DIP switches to configure the serial data radios to use these parame...

Page 2: ...radio that comes into the network The Master Radio should only be in Routed mode if used in a Point to Point Network Broadcast Mode Broadcast mode allows for more flexible radio layouts and is used i...

Page 3: ...MultiHop radios is the most powerful wireless system possible many repeaters and slaves can be combined to cover vast areas and get around hills or buildings In the other networks the wireless hops ar...

Page 4: ...ne master radio and one slave radio synchronizes quickly after power up larger MultiHop networks may take a few minutes to synchronize First all radios within range of the master data radio wirelessly...

Page 5: ...kbps 2 4 GHz 250 kbps Supply Voltage 10 V DC to 30 V DC Outside the USA 12 V DC to 24 V DC 10 1 Average Current for 900 MHz Radios 1500 byte packets at 50 ms intervals Master Mode 0 12 A at 12 V 0 06...

Page 6: ...traight 40 Typ 14 5 M12 x 1 44 Typ 14 5 M12 x 1 1 4 5 3 2 2 3 4 1 5 MQDEC 503SS 0 91 m 2 99 ft 1 Brown 2 White 3 Blue 4 Black 5 Gray MQDEC 506SS 1 83 m 6 ft MQDEC 512SS 3 66 m 12 ft MQDEC 515SS 5 m 16...

Page 7: ...g agencies This device has been designed to operate with the antennas listed on Banner Engineering s website and having a maximum gain of 9 dBm Antennas not included in this list or having a gain grea...

Page 8: ...he product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty Any modifications to this product without prior express...