Specifications

Radio Range

900 MHz, 1 Watt: Up to 3.2 km (2 miles) with line of sight (internal antenna)

2.4 GHz, 65 mW: Up to 1000 m (3280 ft) with line of sight (internal antenna)

Antenna Minimum Separation Distance

900 MHz, 150 mW and 250 mW: 2 m (6 ft)

900 MHz, 1 Watt: 4.57 m (15 ft)

2.4 GHz, 65 mW: 0.3 m (1 ft)

Radio Transmit Power

900 MHz, 1 Watt: 30 dBm (1 W) conducted (up to 36 dBm EIRP)

2.4 GHz, 65 mW: 18 dBm (65 mW) conducted, less than or equal to 20 dBm (100 mW)

EIRP

Radio Packet Size (SRM-H and HL)

1500 bytes, maximum

900 MHz Compliance

Radio module is indicated by the product label marking

Contains FCC ID: UE3RM7023: FCC Part 15, Subpart C, 15.247

Contains IC: 7044A-RM7023

2.4 GHz Compliance (SX243 Radio Module)

Radio module is indicated by the product label marking

Contains FCC ID: UE3SX243: FCC Part 15, Subpart C, 15.247

Radio Equipment Directive (RED) 2014/53/EU

Contains IC: 7044A-SX243

ANATEL: 03737-22-04042 Este equipamento não tem direito à proteção contra

interferência prejudicial e não pode causar interferência em sistemas devidamente

autorizados. Para maiores informações, consulte o site da ANATEL 

www.gov.br/

anatel/pt-br/

Spread Spectrum Technology

FHSS (Frequency Hopping Spread Spectrum)

Communication Hardware

Interface: 2-wire half-duplex RS-485

Baud rates: 9600, 19.2k (default)

Data format: 8 data bits, 1 stop bit, no parity (default)

Radio Data Transfer Rate

900 MHz: 300 kbps

2.4 GHz: 250 kbps

Supply Voltage

10 V DC to 30 V DC (Outside the USA: 12 V DC to 24 V DC, ± 10%)

1

Average Current for 900 MHz Radios (1500 byte packets at 50 ms intervals)

Master Mode: 0.12 A at 12 V; 0.06 A at 24 V

Slave Mode: 0.03 A at 12 V; 0.017 A at 24 V

Average Current for 2.4 GHz Radios (1500 byte packets at 50 ms intervals

Master Mode: 0.035 A at 12 V; 0.02 A at 24 V

Slave Mode: 0.022 A at 12 V; 0.014 A at 24 V

Interface

Two bi-color LED indicators

One button (under the small round cover)

Construction

TBD

Shock and Vibration

All models meet IEC 60068-2-6 and IEC 60068-2-27 testing criteria

Shock: 30G 11 ms duration, half sine wave per IEC 60068-2-27

Vibration: 10 Hz to 55 Hz, 0.5 mm peak-to-peak amplitude per IEC 60068-2-6

Operating Conditions

–40 °C to +85 °C (–40 °F to +185 °F)

95% maximum relative humidity (non-condensing)

Radiated Immunity: 10 V/m (EN 61000-4-3)

Operating the devices at the maximum operating conditions for extended periods can

shorten the life of the device.

Environmental Ratings

IP65

For installation and waterproofing instructions, go to 

www.bannerengineering.com

 and

search for the complete instruction manual

Certifications

Banner Engineering Europe Park

Lane, Culliganlaan 2F bus 3, 1831

Diegem, BELGIUM

(CE/UKCA approval only

applies to 2.4 GHz

models)

Turck Banner LTD Blenheim

House, Blenheim Court, Wickford,

Essex SS11 8YT, Great Britain

1

For European applications, power this device from a Limited Power Source as defined in EN 60950-1.

Sure Cross

®

 R70SR Serial Data Radio

 

 

P/N 224673 Rev. B

www.bannerengineering.com - Tel: + 1 888 373 6767

5

Summary of Contents for Sure Cross R70SR Series

Page 1: ...work Connect your serial devices using a serial cable Note the baud rate and parity of your serial devices so that you can use the DIP switches to configure the serial data radios to use these parame...

Page 2: ...radio that comes into the network The Master Radio should only be in Routed mode if used in a Point to Point Network Broadcast Mode Broadcast mode allows for more flexible radio layouts and is used i...

Page 3: ...MultiHop radios is the most powerful wireless system possible many repeaters and slaves can be combined to cover vast areas and get around hills or buildings In the other networks the wireless hops ar...

Page 4: ...ne master radio and one slave radio synchronizes quickly after power up larger MultiHop networks may take a few minutes to synchronize First all radios within range of the master data radio wirelessly...

Page 5: ...kbps 2 4 GHz 250 kbps Supply Voltage 10 V DC to 30 V DC Outside the USA 12 V DC to 24 V DC 10 1 Average Current for 900 MHz Radios 1500 byte packets at 50 ms intervals Master Mode 0 12 A at 12 V 0 06...

Page 6: ...traight 40 Typ 14 5 M12 x 1 44 Typ 14 5 M12 x 1 1 4 5 3 2 2 3 4 1 5 MQDEC 503SS 0 91 m 2 99 ft 1 Brown 2 White 3 Blue 4 Black 5 Gray MQDEC 506SS 1 83 m 6 ft MQDEC 512SS 3 66 m 12 ft MQDEC 515SS 5 m 16...

Page 7: ...g agencies This device has been designed to operate with the antennas listed on Banner Engineering s website and having a maximum gain of 9 dBm Antennas not included in this list or having a gain grea...

Page 8: ...he product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty Any modifications to this product without prior express...

Reviews: