Emitter
Bi-color red/green Status indicator
—shows whether power is applied, and
whether the emitter is in RUN mode (green) or Lockout condition (flashing
red) .
1-Digit Diagnostic Display
—indicates configuration or specific error
conditions.
Status Indicator
Diagnostic Display
Figure 6. Status Indicators—Emitter
Receiver
Bi-color red/green Status indicator
—shows system status:
• outputs are ON or OFF (green ON or red OFF), or
• the System is in Lockout condition (flashing red)
Amber RUN mode indicator
—shows system status:
• RUN mode (ON), or
• Lockout (OFF)
1-Digit Diagnostic Display
—indicates configuration or specific error
conditions, or the total number of blocked beams.
Bi-color red/green Alignment indicators
—show status of a group of beams
(+/- 35 mm of indicator) along the length of the exit window:
• aligned and clear (green ON), or
• blocked and/or misaligned (red ON),
• fixed blanked area (flashing green),
• lockout (all OFF), or
• Beam 1 (sync) is blocked (Alignment Indicator 1 is red and all others
are OFF).
Run Mode Indicator
Status Indicator
Diagnostic Display
Alignment Indicator(s)
Figure 7. Status Indicators—Receiver