S
Self-Checking (Circuitry)
A circuit with the capability to electronically verify
that all of its own critical circuit components, along
with their redundant backups, are operating properly.
Banner safety light screen systems and safety
modules are self-checking.
Safety Distance
The minimum distance required to allow the
machine’s hazardous motion to stop completely,
before a hand (or other object) can reach the nearest
hazard point. Measured from the midpoint of the
defined area to the nearest hazard point. Factors that
influence minimum separation distance include the
machine stop time, the light screen system response
time, and the light screen minimum object detection
size.
Specified Test Piece
An opaque object of sufficient size used to block a
light beam to test the operation of a safety light
screen system. When inserted into the defined area
and placed in front of a beam, the test piece causes
the outputs to de-energize.
Supplemental Guarding
Additional safeguarding device(s) or hard guarding,
used to prevent a person from reaching over, under,
through or around the primary safeguard or
otherwise accessing the guarded hazard.
T
Test Piece
An opaque object of sufficient size used to block a
light beam to test the operation of a safety light
screen system.
U
UL (Underwriters Laboratory)
A third-party organization that tests products for
compliance with appropriate standards, electrical
codes, and safety codes. Compliance is indicated by
the UL listing mark on the product.
EZ-SCREEN
®
LS Safety Light Screen
100
www.bannerengineering.com - Tel: +1.763.544.3164