background image

Figure 13. SI-QM-SSA-2 dimensions

Figure 14. SI-QM-SSA-2RA dimensions

 

 

SI-GL42 Series Locking-Style Safety Interlock Switch

 

www.bannerengineering.com - Tel: + 1 888 373 6767

19

Summary of Contents for SI-GL42 Series

Page 1: ...SI GL42 Series Locking Style Safety Interlock Switch Instruction Manual Original Instructions 220476 Rev A 22 January 2021 Banner Engineering Corp All rights reserved 220476...

Page 2: ...4 Access the Wiring Chamber 13 2 4 1 Wiring the Terminals 13 2 5 Connection to a Machine 13 3 Operating Instructions 16 3 1 Checkout Procedures 16 3 1 1 Initial and Daily Checks 16 3 1 2 Periodic Chec...

Page 3: ...ions 1 1 Models A complete safety system is typically made up of two interlocks two actuators two cables and a safety monitoring device The use of an emergency release mechanism depends on the applica...

Page 4: ...1 24 V AC DC 1 NO 2 NC 1 NO Actuator Contacts Solenoid Monitor Contacts 43 44 E1 E2 13 14 31 32 21 22 Actuator Contacts Solenoid Monitor Contacts 43 44 E1 E2 13 14 31 32 21 22 Actuator Contacts Soleno...

Page 5: ...than otherwise possible in applications where the guard can be opened and the hazard can be accessed A guard can be a gate door cover panel barrier or other physical means that separates individuals f...

Page 6: ...al obstruction mounting in a concealed position Mounting them securely so that their physical position cannot shift using reliable fasteners that require a tool to remove Preventing the switch or the...

Page 7: ...ugh the use of rings or guards If any areas within the guarded area are not visible from the reset switch additional safeguarding must be provided WARNING Perimeter guarding applications Failure to ob...

Page 8: ...e switch length If vertical actuation is required move the small cover from the opening in the top of the head to the opening in the side of the head To rotate the head 1 Loosen the four screws TX10 o...

Page 9: ...r Figure 3 Actuator dimensions and necessary minimal travel Screw on Surface Y X p p X 29 3 Y 29 3 Necessary Minimal Travel When the actuator is withdrawn from the switch s head the active axis must b...

Page 10: ...open 25 mm The end of the tongue will still be in the opening of the switch head The head must still be equipped with an anti rotation device 5 Tighten the small alignment screw 1 to 1 5 N m 6 Open a...

Page 11: ...The NC contacts marked with this symbol will open 3 Turn the release element back to its original position locked before restarting normal operation 4 Screw in the lock screw 0 5 N m and seal in place...

Page 12: ...the mounting screw position 2 While holding the lever in the counterclockwise direction insert the key in the small slot near the lower mounting screw You should feel some resistance 3 Turn the lever...

Page 13: ...tuator is present this contact signifies the closed position and the locking status of the guard so it can be checked by the monitoring device of the safety circuit per ISO 14119 When using the lockin...

Page 14: ...ule 2 channel E stop Module 2 channel Gate Monitor Module etc Single gate or guard Solenoid Monitor Contact Solenoid Monitor Contact Locking for personnel protection Refer to the installation instruct...

Page 15: ...ISO 13849 1 of a machine stop circuit In addition normally closed N C safety contacts from each of the two safety switches should be connected to the two separate inputs of a two channel safety monito...

Page 16: ...trained to perform a specified checkout procedure 1 Inspect for breakage of the switch body or actuator 2 Verify good alignment and full engagement of the actuator 3 Confirmation that the safety switc...

Page 17: ...ion Glass fiber reinformed polyamide thermoplastic UL94 V0 enclosure and cover Glass fiber reinformed polyamide thermoplastic UL94 V0 and zinc diecast actuating device Maximum Approach Speed Vmax 0 5...

Page 18: ...Figure 11 SI QM SMFA 2 dimensions 1 2 Figure 12 SI QM SMFA 3 dimensions SI GL42 Series Locking Style Safety Interlock Switch 18 www bannerengineering com Tel 1 888 373 6767...

Page 19: ...Figure 13 SI QM SSA 2 dimensions Figure 14 SI QM SSA 2RA dimensions SI GL42 Series Locking Style Safety Interlock Switch www bannerengineering com Tel 1 888 373 6767 19...

Page 20: ...k Switch SI LS100 Safety Interlock Switch SI QS90 Safety Interlock Switch RP LS42 Rope Pull Switch 5 3 Cable Glands Model Size For Cable Diameter Dimensions Used With SI QS CGM20 M20 1 5 Plastic 5 0 t...

Page 21: ...dels Expandable Models Description SC26 2 XS26 2 26 convertible I O and 2 Redundant Solid State Safety Outputs SC26 2d XS26 2d 26 convertible I O and 2 Redundant Solid State Safety Outputs with Displa...

Page 22: ...ct THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AN...

Reviews: