background image

 

July 07, 2023

page 

6

R70ER Ethernet Data Radio

900 MHz Compliance

Radio module is indicated by the product label marking
Contains FCC ID: UE3RM7023: FCC Part 15, Subpart C, 
15.247

Contains IC: 7044A-RM7023 

2.4 GHz Compliance (SX243 Radio Module)

Radio module is indicated by the product label marking
Contains FCC ID: UE3SX243: FCC Part 15, Subpart C, 
15.247
Radio Equipment Directive (RED) 2014/53/EU
ETSI/EN: EN 300 328 V2.2.2 (2019-07) [RED HarmStds]
Contains IC: 7044A-SX243

ANATEL: 03737-22-04042   

Radio Data Transfer Rate

 

900 MHz: 300 kbps

 

 

2.4 GHz: 250 kbps

 

Supply Voltage

 

10 V DC to 30 V DC

 (

Outside the USA: 12 V DC to 24 V DC, 

± 10%

For European applications, power this device from a Limited 

Power Source as defined in EN 60950-1. 

Average Current for 900 MHz Radios (1500 byte packets at 50 ms 

intervals)

 Client Mode: 0.12 A at 12 V; 0.06 A at 24 V
 Server Mode: 0.03 A at 12 V; 0.017 A at 24 V 

Average Current for 2.4 GHz Radios (1500 byte packets at 50 ms 

intervals

 Client Mode: 0.035 A at 12 V; 0.02 A at 24 V
 Server Mode: 0.022 A at 12 V; 0.014 A at 24 V

Interface

Two bi-color LED indicators

 

One button

 (under the small round cover)

Construction

Base: Black polycarbonate
Cover: Translucent gray polycarbonate

Operating Conditions

 –40 °C to +85 °C (–40 °F to +185 °F)
 

95% maximum relative humidity (non-condensing)

Radiated Immunity: 

10 V/m (EN 61000-4-3)

Operating the devices at the maximum operating conditions 
for extended periods can shorten the life of the device.

Environmental Ratings

IP65

 

For installation and waterproofing instructions, go 

to 

www.bannerengineering.com

 and search for the complete 

instruction manual

Shock and Vibration

All models meet IEC 60068-2-6 and IEC 60068-2-27 testing 
criteria
Shock: 30G 11 ms duration, half sine wave per IEC 
60068-2-27
Vibration: 10 Hz to 55 Hz, 0.5 mm peak-to-peak amplitude per 
IEC 60068-2-6

Certifications

Banner Engineering BV
Park Lane, Culliganlaan 2F bus 3
1831 Diegem, BELGIUM

(CE/UKCA approval only applies to 2.4 GHz models)

FCC Part 15 Class A 

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These 
limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial 
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the 
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to 

cause harmful interference in which case the user will be required to correct the interference at his own expense.  

Industry Canada Statement for Intentional Radiators 

This device contains licence-exempt transmitters(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s 

licence-exempt RSS(s). Operation is subject to the following two conditions:

Cet appareil contient des émetteurs/récepteurs exemptés de licence conformes à la norme Innovation, Sciences, et Développement 

économique Canada. L’exploitation est autorisée aux deux conditions suivantes:

R70ER Dimensions

All measurements are listed in millimeters, unless noted otherwise.

 

This device may not cause interference. 

1. 

This device must accept any interference, including interference that may cause undesired operation of the device. 

2. 

L’appareil ne doit pas produire de brouillage. 

1. 

L’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre 
le fonctionnement. 

2. 

© Banner Engineering Corp.

Summary of Contents for R70ER

Page 1: ...ER2MQ 2 4 GHz ISM Band 65 mW 100 mW EIRP Quick Start Guide Set Up Your R70ER Radio Network Each radio network should include one controller primary radio and several repeater or peripheral radios To s...

Page 2: ...192 168 18 18 peripheral radio OFF ON ON XML Bypassed Static IP 192 168 17 17 controller radio ON ON ON Radio board DIP switch settings closest to binding button Radio Transmit Power 900 MHz Only DIP...

Page 3: ...o the other end This allows the radio system to automatically correct for transmission problems and it also provides the greatest throughput This is the fastest configuration Controller configuration...

Page 4: ...e R70ER For a list of splitter and cordset options see R70ER Accessories on page 7 4 pin M12 Male Connector Pin Wire Color Wiring Description 1 4 3 2 1 Brown bn 10 to 30 V DC 2 White wh Reserved 3 Blu...

Page 5: ...parent device Flashes red 3 A parent device is detected The client repeater searches for other parent radios within range Solid red 4 The server repeater selects a suitable parent Solid amber 5 The se...

Page 6: ...hock 30G 11 ms duration half sine wave per IEC 60068 2 27 Vibration 10 Hz to 55 Hz 0 5 mm peak to peak amplitude per IEC 60068 2 6 Certifications Banner Engineering BV Park Lane Culliganlaan 2F bus 3...

Page 7: ...14 5 0 57 M12 x 1 Female 2 3 4 1 Male 1 4 3 2 1 Brown 2 White 3 Blue 4 Black MQDEC 403SS 0 91 m 2 99 ft MQDEC 406SS 1 83 m 6 ft MQDEC 412SS 3 66 m 12 ft MQDEC 420SS 6 10 m 20 ft MQDEC 430SS 9 14 m 30...