background image

 

July 07, 2023

page 

10

R70ER Ethernet Data Radio





impedance is 50 ohms. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen such that the 
equivalent isotropically radiated power (EIRP) is not more than that permitted for successful communication. Consult with Banner 
Engineering Corp. if the destination country is not on this list.

 

IMPORTANT:

Never operate a 1 Watt radio without connecting an antenna
Operating 1 Watt radios without an antenna connected will damage the radio circuitry.
To avoid damaging the radio circuitry, never apply power to a Sure Cross® Performance or Sure Cross 
MultiHop (1 Watt) radio without an antenna connected.

IMPORTANT:

Electrostatic discharge (ESD) sensitive device
ESD can damage the device. Damage from inappropriate handling is not covered by warranty.
Use proper handling procedures to prevent ESD damage. Proper handling procedures include leaving devices 
in their anti-static packaging until ready for use; wearing anti-static wrist straps; and assembling units on a 
grounded, static-dissipative surface.

Banner Engineering Corp Limited Warranty 

Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of 
shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to 
the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or 

the improper application or installation of the Banner product. 

THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED 
(INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND 
WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE.

 

This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement.  IN NO EVENT SHALL 

BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, 
LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT 
DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, 
TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.

 

Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or 
liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or 
installation of this product or use of the product for personal protection applications when the product is identified as not intended for such 
purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will 
void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product 
specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in 

any other language. For the most recent version of any documentation, refer to: 

www.bannerengineering.com

For patent information, see 

www.bannerengineering.com/patents

Document title: Sure Cross® MultiHop R70ER Ethernet Data Radio
Part number: 226574
Revision: B
Original Instructions
© Banner Engineering Corp. All rights reserved.

© Banner Engineering Corp.

Summary of Contents for R70ER

Page 1: ...ER2MQ 2 4 GHz ISM Band 65 mW 100 mW EIRP Quick Start Guide Set Up Your R70ER Radio Network Each radio network should include one controller primary radio and several repeater or peripheral radios To s...

Page 2: ...192 168 18 18 peripheral radio OFF ON ON XML Bypassed Static IP 192 168 17 17 controller radio ON ON ON Radio board DIP switch settings closest to binding button Radio Transmit Power 900 MHz Only DIP...

Page 3: ...o the other end This allows the radio system to automatically correct for transmission problems and it also provides the greatest throughput This is the fastest configuration Controller configuration...

Page 4: ...e R70ER For a list of splitter and cordset options see R70ER Accessories on page 7 4 pin M12 Male Connector Pin Wire Color Wiring Description 1 4 3 2 1 Brown bn 10 to 30 V DC 2 White wh Reserved 3 Blu...

Page 5: ...parent device Flashes red 3 A parent device is detected The client repeater searches for other parent radios within range Solid red 4 The server repeater selects a suitable parent Solid amber 5 The se...

Page 6: ...hock 30G 11 ms duration half sine wave per IEC 60068 2 27 Vibration 10 Hz to 55 Hz 0 5 mm peak to peak amplitude per IEC 60068 2 6 Certifications Banner Engineering BV Park Lane Culliganlaan 2F bus 3...

Page 7: ...14 5 0 57 M12 x 1 Female 2 3 4 1 Male 1 4 3 2 1 Brown 2 White 3 Blue 4 Black MQDEC 403SS 0 91 m 2 99 ft MQDEC 406SS 1 83 m 6 ft MQDEC 412SS 3 66 m 12 ft MQDEC 420SS 6 10 m 20 ft MQDEC 430SS 9 14 m 30...

Page 8: ...4 5 M12 x 1 7 mm 58 mm 5 2 mm 2 3 4 1 5 1 Brown 2 White 3 Blue 4 Black 5 Unused MQDC 415 5 m 16 4 ft MQDC 430 9 m 29 5 ft MQDC 450 15 m 49 2 ft MQDC 406RA 2 m 6 56 ft Right Angle 32 Typ 1 26 30 Typ 1...

Page 9: ...T Veuillez t l charger la documentation technique compl te des Sure Cross R70ER Ethernet Data Radio sur notre site www bannerengineering com pour les d tails sur leur utilisation correcte les applicat...

Page 10: ...IES WHETHER EXPRESS OR IMPLIED INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND WHETHER ARISING UNDER COURSE OF PERFORMANCE COURSE OF DEALING OR TRA...