Q5Z Global Laser Measurement Sensor with IO-Link Quick Start Guide

Class 2 Red Laser models: Reference IEC 60825­1:2014 

FDA (CDRH) warning label (Class 2)

LASER LIGHT

DO NOT STARE INTO BEAM

CLASS 2 LASER PRODUCT

IEC 60825-1:2014. Wavelength

640-670nm; 1.0mW max. Complies with

21 CFR 1040.10 and 1040.11 except for

conformance with IEC 60825-1: 2014

as described in Laser Notice

 No. 56, dated May 8, 2019.

Output:

 < 1.0 mW 

Laser wavelength:

 640 to 670 nm 

Pulse Duration for <5 m Models:

 20 µs to 2 ms

Pulse Duration for ≥ 5 m Models: 3 µs 

Features

The following shows the simplified user interface of the 

Q5Z

Q5Z

 Features

1

2

3

Use the sensor button 

(TEACH)

 to program the sensor. 

Press and hold for longer than 2 seconds to start the pre-

configured TEACH mode. 

Top View

Installation

Sensor Orientation for the Triangulation Models

Optimize detection reliability and minimum object separation performance with correct sensor­to­target orientation. 

To ensure reliable detection, orient the sensor as shown in relation to the target to be detected. 

Optimal Orientation of Target to Sensor 

See the following figures for examples of correct and incorrect sensor-to-target orientation as certain placements may pose problems for 

sensing some targets. The 

Q5Z

 can be used in the less preferred orientation and at steep angles of incidence and still provide reliable detec­

tion performance due to its high excess gain. For the minimum object separation distance required for each case, refer to 

"Performance 

Curves 

" on page 5

Chanel 1 output indicator (amber) 

1. 

Chanel 2 output indicator (amber) 

2. 

Button 

3. 