NOTE: Cabled hookups are shown. QD hookups are functionally identical.

Specifications

Supply Voltage and Current

10 V dc to 30 V dc (10% max. ripple); supply current (exclusive of load

current):
Emitters: 25 mA
Receivers: 20 mA
Polarized Retroreflective: 30 mA
Fixed-Field: 35 mA

Supply Protection Circuitry

Protected against reverse polarity and transient voltages

Output Configuration

SPDT solid-state dc switch; NPN (current sinking) or PNP (current

sourcing) outputs, depending on model
Light Operate: N.O. (normally open) output conducts when sensor

sees its own (or the emitter’s) modulated light
Dark Operate: N.C. (normally closed) output conducts when the

sensor sees dark; the N.C. output may be wired as a normally open

marginal signal alarm output, depending upon hookup to power supply

Environmental Rating

Leakproof design rated NEMA 6P, DIN 40050 (IEC IP69K)

Construction

PBT polyester housing; polycarbonate (opposed-mode) or acrylic lens

Required Overcurrent Protection

WARNING: Electrical connections must be

made by qualified personnel in accordance

with local and national electrical codes and

regulations.

Overcurrent protection is required to be provided by end product

application per the supplied table.
Overcurrent protection may be provided with external fusing or via

Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to 

http://

www.bannerengineering.com

.

Supply Wiring (AWG)

Required Overcurrent Protection (Amps)

20

5.0

22

3.0

24

2.0

26

1.0

28

0.8

30

0.5

Output Rating

150 mA maximum (each) in standard hookup. When wired for alarm

output, the total load may not exceed 150 mA.
OFF-state leakage current: < 1 µA at 30 V dc
ON-state saturation voltage: < 1 V at 10 mA dc; < 1.5 V at 150 mA

dc

Output Protection Circuitry

Protected against false pulse on power-up and continuous overload or

short circuit of outputs

Output Response Time

Opposed mode: 3 ms ON, 1.5 ms OFF
Retro, Fixed-Field and Diffuse: 3 ms ON and OFF

NOTE: 100 ms delay on power-up; outputs

do not conduct during this time

Repeatability

Opposed mode: 375 

μ

s

Retro, Fixed-Field and Diffuse: 750 

μ

s

Repeatability and response are independent of signal strength

Indicators

Two LEDs (Green and Amber)
Green ON steady: power to sensor is ON
Green flashing: output is overloaded
Amber ON steady: N.O. output is conducting
Amber flashing: excess gain marginal (1 to 1.5 times) in light

condition

Connections

2 m (6.5 ft) or 9 m (29.5 ft) attached cable or 4-pin Euro-style quick-

disconnect fitting

Operating Conditions

Temperature: 

40 °C to +70 °C (

40 °F to +158 °F)

Humidity: 90% at +50 °C maximum relative humidity (non-

condensing)

Vibration and Mechanical Shock

All models meet Mil. Std. 202F requirements. Method 201A (Vibration;

frequency 10 Hz to 60 Hz, max., double amplitude 0.06 inch

acceleration 10G). Method 213B conditions H&I. (Shock: 75G with unit

operating; 100G for non-operation)

Certifications

Banner Engineering Corp. Limited Warranty

Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp.

will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty

period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.

THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION,

ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE

OF DEALING OR TRADE USAGE.

This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE

LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL,

CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER

ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE.

Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product

previously manufactured by Banner Engineering Corp.

 

 

Q25 DC Sensors

 

www.bannerengineering.com - Tel: +1-763-544-3164

 

Reviews: