Banner MINI-BEAM Expert Series Quick Start Manual Download Page 1

Quick Start Guide

Microprocessor-Based TEACH Mode Photoelectric Sensors

U.S. patent(s) issued or pending

This guide is designed to help you set up and install the MINI-BEAM

®

 Expert

. For

complete information on programming, performance, troubleshooting, dimensions,

and accessories, please refer to the Instruction Manual at 

www.bannerengineering.com

. Search for p/n 55214 to view the Instruction Manual.

Use of this document assumes familiarity with pertinent industry standards and

practices.

WARNING: Not To Be Used for Personnel Protection

Never use this device as a sensing device for personnel

protection. Doing so could lead to serious injury or death.

This device does not include the self-checking redundant

circuitry necessary to allow its use in personnel safety

applications. A sensor failure or malfunction can cause either an

energized or de-energized sensor output condition.

Models

Retroreflective Models

Model1

Sensing Mode

Range or Focus2

Supply Voltage

Output Type

SME312LV

Retroreflective, Visible red, 650 nm

5 m (15 ft)

10 V dc to 30 V dc

Bipolar NPN/PNP

SME312LP

Polarized retroreflective, Visible red, 650 nm

10 mm to 3 m (0.4 in to 10 ft)

SME312LPC

Polarized retroreflective, Visible red, 650 nm
(clear object)

1 m (3.3 ft) with supplied reflector

Diffuse Models

Model1

Sensing Mode

Range or Focus

Supply Voltage

Output Type

SME312D

Diffuse, Infrared, 880 nm

380 mm (15 in)

10 V dc to 30 V dc

Bipolar NPN/PNP

SME312DV

Diffuse, Visible red, 650 nm

1100 mm (43 in)

SME312W

Divergent Diffuse, Infrared, 880 nm

130 mm (5 in)

Convergent Models

Model1

Sensing Mode

Range or Focus

Spot Size at Focus

Supply Voltage

Output Type

SME312CV

Convergent, Visible red, 650 nm

16 mm (0.65 in)

1.3 mm (0.05 in)

10 V dc to 30 V dc

Bipolar NPN/PNP

SME312CV2

Convergent, Visible red, 650 nm

43 mm (1.7 in)

3.0 mm (0.12 in)

SME312CVG

Convergent, Visible green, 525 nm

16 mm (0.65 in)

1.0 mm (0.04 in)

SME312CVB

Convergent, Visible blue, 475 nm

16 mm (0.65 in)

1.8 mm (0.07 in)

SME312CVW

Convergent, Visible white, 450–650 nm

1 Standard 2 m (6.5 ft) cable models are listed. To order the 9 m (30 ft) cable model, add suffix “W/30” to the model number (for example,

SME312LV W/30.) To order the 5-pin Euro-style QD models, add suffix “QD” (for example, SME312LVQD). Models with a QD connector require a

mating cable.

2 Sensing ranges vary according to the efficiency and reflective area of the retroreflector(s) used. (Retroreflective tape is not recommended for use

with Clear Object Detection models.) See Accessories and the Banner Engineering catalog for more information.

MINI-BEAM Expert Series

 

 

Original Document

68812 Rev. C

13 July 2016

68812

Summary of Contents for MINI-BEAM Expert Series

Page 1: ...ible red 650 nm clear object 1 m 3 3 ft with supplied reflector Diffuse Models Model1 Sensing Mode Range or Focus Supply Voltage Output Type SME312D Diffuse Infrared 880 nm 380 mm 15 in 10 V dc to 30 V dc Bipolar NPN PNP SME312DV Diffuse Visible red 650 nm 1100 mm 43 in SME312W Divergent Diffuse Infrared 880 nm 130 mm 5 in Convergent Models Model1 Sensing Mode Range or Focus Spot Size at Focus Sup...

Page 2: ...or configuration setting the sensitivity threshold and selecting output ON and OFF conditions is performed in TEACH mode The two LED indicators bi color green red and amber have distinct roles in the two operation modes If contrast is marginal the bi color indicator will flash green to indicate instability If this occurs reconfigure or realign the sensor or clean the sensor or fiber lenses The Sig...

Page 3: ...ied with the fiber on each fiber end as shown in the drawing 2 While pressing the fiber ends firmly into the ports on the sensor front slide the U shaped retaining clip supplied with the sensor into the slot in the sensor s barrel until it snaps into place Plastic Fiber Installation Trimmed fiber control ends Plastic fiber emitter port Plastic fiber receiver port Gripper Unlock Lock Adapters for 0...

Page 4: ...ondition and is ready for the output OFF condition Via remote line Present the first sensing condition and single pulse the remote line 3 Teach the second sensing condition and return to RUN mode Method Action Result Via push button Present the second sensing condition and click the push button If the teach is accepted the green LED is on or flashes if the signal is close to the switching threshol...

Page 5: ... flashes red green this indicates a microprocessor memory error To clear the error re teach the sensor or cycle the power ON and OFF and re teach the sensor If this does not solve the problem or if it occurs frequently replace the sensor Banner Engineering Corp Limited Warranty Banner Engineering Corp warrants its products to be free from defects in material and workmanship for one year following ...

Reviews: