4.3 Receiver Specifications
Supply Voltage at the Device
24 V dc ±15% (use a SELV-rated power supply according to EN IEC
60950). The external voltage supply must be capable of buffering brief
mains interruptions of 20 ms, as specified in IEC/EN 60204-1.
Residual Ripple
±10% maximum
Supply Current (no load)
150 mA maximum, exclusive of OSSD1 and OSSD2 loads (up to additional
0.5 A each) and Aux Out load (up to 0.25 A)
Supply Current (no load)
150 mA maximum, exclusive of OSSD1 and OSSD2 loads (up to additional
0.5 A each) and Fault Out load (up to 0.10 A)
Response Time
Dependent on the number of sensing beams; see the models table for the
number of beams and response time.
EDM Input
+24 V dc signals from external device contacts can be monitored (one-
channel or no monitoring) via EDM1 terminal in the receiver.
High Signal: 10 to 30 V dc at 30 mA typical
Low Signal: 0 to 3 V dc
Recovery Time
Blocked to Clear (OSSDs turn On; varies with total number of sensing
beams and whether Sync beam is blocked):
Model
Beam 1 (Sync Beam)
All Other Beams
14 mm
109 ms to 800 ms
33 ms to 220 ms
25 mm
81 ms to 495 ms
25 ms to 152 ms
Reset Input
Reset input must be high for 0.25 to 2 seconds and then low to reset the
receiver
High Signal: 10 to 30 V dc at 30 mA typical
Low Signal: 0 to 3 V dc
Closed Switch Time: 0.25 to 2 seconds
Mute Lamp Output
A monitored or non-monitored (selectable), current-sourcing (PNP), solid-
state output
Rated Current: 10 mA to 360 mA at 24 V dc
External Remote Indicator Outputs
Current sourcing (PNP), solid-state, 24 V dc outputs for the connection of
remote indicator lamps such as EZ-LIGHTs. See Accessories for
compatible EZ-LIGHTs and associated cordsets.
Rated Current: 100 mA maximum at 24 V dc
Output Signal Switching Devices (OSSDs)
Two redundant solid-state 24 V dc, 0.5 A max. sourcing OSSD
(Output Signal Switching Device) safety outputs. (Use optional
interface modules for ac or larger dc loads.)
Capable of the Banner "Safety Handshake".
ON-State voltage: ≥ Vin-1.5 V dc
OFF-State, maximum allowed external voltage: 1.7 V dc
Maximum load capacitance: 1.0 µF
Minimum load inductance: 10 H
Leakage current: 0.50 mA maximum
OSSD test pulse width: 100 to 300 microseconds typical
OSSD test pulse period: 10 ms to 22 ms (varies with number of
beams)
Switching current: 0 to 0.5 A
Auxiliary Output Switching Capacity (OSSD/Fault)
Current-sourcing (PNP) solid-state output, 24 V dc at 250 mA max.
Controls and Adjustments
Scan Code selection: 2-position switch (code 1 or 2). Factory default
position is code 1
Trip/Latch Output selection: Redundant switches. Factory default
position is T (trip).
Mute Lamp Monitoring: On/Off switch. Factory default position is On.
Reduced Resolution: Redundant switches. Factory default position is
Off.
Aux./Fault: 2-position switch. Factory default position is Aux.
Invert Display: 2-position switch. Factory default position is Off
(standard display).
Status Indicators
Amber Reset Indicator: indicates whether the System is ready for
operation or requires a reset
Bi-color (red/green) Status indicator: indicates general system and
output status
Bi-color (red/green) Zone Status indicators: indicate condition (clear
or blocked beam) of a defined group of beams
7-Segment Diagnostic indicator (1 digit): indicates proper operation,
scan code, error code, or total number of blocked beams
7-Segment Diagnostic indicator (3 digits): indicates proper operation,
scan code, error code, or total number of blocked beams
Amber Mute Device Input Indicators: indicates status of mute device
inputs
Ambient Light Immunity
10,000 lux at 5° angle of incidence
Strobe Light Immunity
Totally immune to one Federal Signal Corp. "Fireball" model FB2PST
strobe
EZ-SCREEN Low-Profile System with Integral Muting
www.bannerengineering.com - Tel: + 1 888 373 6767
15