background image

Installation Guide

Advanced sensor with dual digital displays for use with plastic and glass fiber optic assemblies.

For complete technical information about this product, including dimensions, accessories, and specifications, see 

http://

www.bannerengineering.com

 and search 161999.

Overview

Figure 1. DF-G1 Model Features

1

Output LED

2

LO/DO Switch

3

RUN/PRG/ADJ Mode Switch

4

Lever Action Fiber Clamp

5

Red Signal Level

6

Green Threshold

7

+/SET/- Rocker Button

WARNING: Not To Be Used for Personnel Protection

Never use this device as a sensing device for personnel protection. Doing so could lead to

serious injury or death. This device does not include the self-checking redundant circuitry necessary

to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an

energized or de-energized sensor output condition.

Models

Model

Outputs

Connector

1

DF-G1-NS-2M

Single NPN

2 m (6.5 ft) cable, 4-wire

DF-G1-PS-2M

Single PNP

DF-G1-KS-2M

Dual outputs, 1 push-pull IO-Link and 1

PNP (complementary outputs)

DF-G1-NS-Q5

Single NPN

150 mm (6 in) PVC pigtail, M12 Euro QD connector,

4-pin

DF-G1-PS-Q5

Single PNP

DF-G1-KS-Q5

Dual outputs, 1 push-pull IO-Link and 1

PNP (complementary outputs)

DF-G1-NS-Q7

Single NPN

Integral M8 Pico QD connector, 4-pin

DF-G1-PS-Q7

Single PNP

DF-G1-KS-Q7

Dual outputs, 1 push-pull IO-Link and 1

PNP (complementary outputs)

1 Connector options:

A model with a QD connector requires a mating cordset .

For 9 m cable, change the suffix 2M to 9M in the 2 m model number (example, DF-G1-NS-9M).

For 150 mm (6 in) PVC pigtail, M8 Pico QD connector, 4-pin change the suffix 2M to Q3 in the 2 m model number (example, DF-G1-NS-Q3).

DF-G1 Expert

 Dual Display Fiber Amplifier

 

 

Original Document

161275 Rev. D

9 September 2015

161275

Summary of Contents for Expert DF-G1-NS-2M

Page 1: ...ion can cause either an energized or de energized sensor output condition Models Model Outputs Connector1 DF G1 NS 2M Single NPN 2 m 6 5 ft cable 4 wire DF G1 PS 2M Single PNP DF G1 KS 2M Dual outputs...

Page 2: ...Installing the Fibers Follow these steps to install glass or plastic fibers 1 Open the dust cover 2 Move the fiber clamp forward to unlock it 3 Insert the fiber s into the fiber port s until they stop...

Page 3: ...will result in the most reliable detection TRANSMITTER RECEIVER Single core fiber Multi core fiber Wiring Diagrams NPN Models Remote Programming N O 10 30V dc Load PNP Models Load 10 30 V dc Remote P...

Page 4: ...ton is a 3 way button The positions are engaged by rocking the button left right The SET position is engaged by clicking down the button while the rocker is in the middle position All three button pos...

Page 5: ...1234 Eco 123P diSP 1234 diSP 123P Eco 1234 Eco 123P display flips 180 1234 Gn 8 Fixed Gain Set To scroll through menu lists Press or To enter a choice list or to select and save Click SET To exit a ch...

Page 6: ...ated signal Output OFF Output ON Darkest Taught Condition Lightest Taught Condition Position adjusted by Manual Adjust Figure 2 Two Point TEACH Light Operate shown The Output ON and OFF conditions can...

Page 7: ...shown Output ON and OFF conditions can be reversed using the LO DO switch Light SET Sets a threshold a programmable offset below the presented condition Changes output state on any condition darker t...

Page 8: ...presented and the sensor positions a threshold exactly at the presented condition When a condition lighter than the threshold is sensed the output either turns ON or OFF depending on the LO DO setting...

Page 9: ...IL without Offset Presented condition cannot be used for the SET method Threshold Alert or Threshold Error Severe contamination changes in the taught condition can prevent the Auto Thresholds algorith...

Page 10: ...ect or 150 mm 6 in cable with a 4 pin M12 Euro style quick disconnect or 150 mm 6 in cable with a 4 pin M8 Pico style quick disconnect Environmental Rating IEC IP50 NEMA 1 Operating Conditions Tempera...