background image

Specifications

Sensing Beam

660 nm visible red

Supply Voltage

NPN/PNP models: 10 to 30 V dc Class 2 (10% maximum ripple)
IO-Link models: 18 to 30 V dc (10% maximum ripple)

Power and Current Consumption (exclusive of load)

Standard display mode: 960 mW, Current consumption < 40 mA at

24 V dc
ECO display mode: 720 mW, Current consumption < 30 mA at 24 V

dc

Supply Protection Circuitry

Protected against reverse polarity and transient overvoltages

Delay at Power-Up

500 milliseconds maximum; outputs do not conduct during this time

Output Configuration

NPN/PNP models: 1 current sinking (NPN) or 1 current sourcing

(PNP) output, depending on model
IO-Link models: 1 push-pull and 1 PNP (complementary outputs)

Required Overcurrent Protection

WARNING: Electrical connections must be

made by qualified personnel in accordance

with local and national electrical codes and

regulations.

Overcurrent protection is required to be provided by end product

application per the supplied table.
Overcurrent protection may be provided with external fusing or via

Current Limiting, Class 2 Power Supply.
Supply wiring leads < 24 AWG shall not be spliced.
For additional product support, go to 

http://

www.bannerengineering.com

.

Supply Wiring

Required Overcurrent Protection

20

5.0 Amps

22

3.0 Amps

24

2.0 Amps

26

1.0 Amps

28

0.8 Amps

30

0.5 Amps

Output Rating

100 mA maximum load (derate 1 mA per °C above 30 °C)
OFF-state leakage current: NPN/PNP models: < 5 

μ

A at 30 V dc;

IO-Link models: < 50 

μ

A at 30 V dc

ON-state saturation voltage: NPN: < 1.5 V; PNP /IO-Link: < 2 V

Output Protection

Protected against output short-circuit, continuous overload, transient

overvoltages, and false pulse on power-up

Output Response Time

High Speed: 200 µs; Standard: 500 µs; Long Range: 2 ms; Extra Long

Range: 5 ms

Repeatability

High Speed: 66 µs, Standard/Long Range/Extra Long Range: 100 µs

Construction

Black ABS/polycarbonate alloy (UL94 V-0 rated) housing, clear

polycarbonate cover

Connections

PVC-jacketed 2 m or 9 m (6.5 ft. or 30 ft.) 4-wire integral cable; or

integral 4-pin M8/Pico-style quick disconnect; or 150 mm (6 in.) cable

with a 4-pin M12/Euro-style quick disconnect; or 150 mm (6 in.) cable

with a 4-pin M8/Pico-style quick disconnect.

Environmental Rating

IEC IP50, NEMA 1

Operating Conditions

Temperature: 

10 °C to +55 °C (+14 °F to +131 °F)

Storage Temperature: 

20 °C to +85 °C (

4 °F to +185 °F)

Humidity: 90% at +60 °C maximum relative humidity (non-

condensing)

IO-Link Interface

Supports Smart Sensor Profile: Yes
Baud Rate: 38,400 bps (COM2)
Process Data Width: 16 bits
IODD files: Provide all programming options of top panel interface,

plus additional functionality, see the DF-G1 Manual (P/N 161999)

Certifications

Industrial
Control
Equipment

3TJJ

Banner Engineering Corp Limited Warranty

Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following

the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture

which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty

does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.

THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR

IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A

PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR

TRADE USAGE.

This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO

EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR

ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR

SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE

PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY,

NEGLIGENCE, OR OTHERWISE.

Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any

obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp.

 

 

DF-G1 Expert

 Dual Display Fiber Amplifier

 

www.bannerengineering.com - Tel: +1-763-544-3164

 

Summary of Contents for Expert DF-G1-NS-2M

Page 1: ...ion can cause either an energized or de energized sensor output condition Models Model Outputs Connector1 DF G1 NS 2M Single NPN 2 m 6 5 ft cable 4 wire DF G1 PS 2M Single PNP DF G1 KS 2M Dual outputs...

Page 2: ...Installing the Fibers Follow these steps to install glass or plastic fibers 1 Open the dust cover 2 Move the fiber clamp forward to unlock it 3 Insert the fiber s into the fiber port s until they stop...

Page 3: ...will result in the most reliable detection TRANSMITTER RECEIVER Single core fiber Multi core fiber Wiring Diagrams NPN Models Remote Programming N O 10 30V dc Load PNP Models Load 10 30 V dc Remote P...

Page 4: ...ton is a 3 way button The positions are engaged by rocking the button left right The SET position is engaged by clicking down the button while the rocker is in the middle position All three button pos...

Page 5: ...1234 Eco 123P diSP 1234 diSP 123P Eco 1234 Eco 123P display flips 180 1234 Gn 8 Fixed Gain Set To scroll through menu lists Press or To enter a choice list or to select and save Click SET To exit a ch...

Page 6: ...ated signal Output OFF Output ON Darkest Taught Condition Lightest Taught Condition Position adjusted by Manual Adjust Figure 2 Two Point TEACH Light Operate shown The Output ON and OFF conditions can...

Page 7: ...shown Output ON and OFF conditions can be reversed using the LO DO switch Light SET Sets a threshold a programmable offset below the presented condition Changes output state on any condition darker t...

Page 8: ...presented and the sensor positions a threshold exactly at the presented condition When a condition lighter than the threshold is sensed the output either turns ON or OFF depending on the LO DO setting...

Page 9: ...IL without Offset Presented condition cannot be used for the SET method Threshold Alert or Threshold Error Severe contamination changes in the taught condition can prevent the Auto Thresholds algorith...

Page 10: ...ect or 150 mm 6 in cable with a 4 pin M12 Euro style quick disconnect or 150 mm 6 in cable with a 4 pin M8 Pico style quick disconnect Environmental Rating IEC IP50 NEMA 1 Operating Conditions Tempera...

Reviews: