Banner Expert DF-G1-NS-2M Installation Manual Download Page 4

Top Panel Interface

Opening the dust cover provides access to the top panel interface. The top panel interface consists of the RUN/PRG/ADJ

mode switch, LO/DO switch, +/SET/- rocker button, dual red/green digital displays, and output LED.

 

 

RUN/PRG/ADJ Mode Switch

The RUN/PRG/ADJ mode switch puts the sensor in RUN, PRG (Program), or ADJ (Adjust) mode. RUN

mode allows the sensor to operate normally and prevents unintentional programming changes via the

+/SET/- rocker button. PRG mode allows the sensor to be programmed through the display-driven

programming menu (see Program Mode below). ADJ mode allows the user to perform Expert

TEACH/SET methods and Manual Adjust (see Adjust Mode below).

 

 

LO/DO Switch

The LO/DO switch selects Light Operate or Dark Operate mode. In Light Operate mode, the output is

ON when the sensing condition is above the threshold. (For Window SET, the output is ON when the

sensing condition is inside the window.) In Dark Operate mode, the output is ON when the sensing

condition is below the threshold. (For Window SET, the output is ON when the sensing condition is

outside the window.)

 

 

+/SET/- Rocker Button

The +/SET/- rocker button is a 3-way button. The +/- positions are engaged by rocking the button left/

right. The SET position is engaged by clicking down the button while the rocker is in the middle position.

All three button positions are used during PRG mode to navigate the display-driven programming menu.

During ADJ mode, SET is used to perform TEACH/SET methods and +/- are used to manually adjust the

threshold(s). The rocker button is disabled during RUN mode, except when using Window SET, see 

Window SET

 on page 7.

 

 

Red/Green Digital Displays

During RUN and ADJ modes, the Red display shows the signal level, and the Green display shows the

threshold. During PRG mode, both displays are used to navigate the display-driven programming menu.

Output LED

The output LED provides a visible indication when the output is activated.

Operating Instructions

Remote Input/IO-Link

For more information about how to perform TEACH/SET methods, to program the sensor remotely, or to interface with the

sensor via IO-Link, see the DF-G1 Manual (P/N 161999).

Run Mode 

Run mode allows the sensor to operate normally and prevents unintentional programming changes. The +/SET/- rocker

button is disabled during RUN mode, except when using Window SET, see 

Window SET

 on page 7.

 

 

DF-G1 Expert

 Dual Display Fiber Amplifier

4

www.bannerengineering.com - Tel: +1-763-544-3164

P/N 161275 Rev. D

Summary of Contents for Expert DF-G1-NS-2M

Page 1: ...ion can cause either an energized or de energized sensor output condition Models Model Outputs Connector1 DF G1 NS 2M Single NPN 2 m 6 5 ft cable 4 wire DF G1 PS 2M Single PNP DF G1 KS 2M Dual outputs...

Page 2: ...Installing the Fibers Follow these steps to install glass or plastic fibers 1 Open the dust cover 2 Move the fiber clamp forward to unlock it 3 Insert the fiber s into the fiber port s until they stop...

Page 3: ...will result in the most reliable detection TRANSMITTER RECEIVER Single core fiber Multi core fiber Wiring Diagrams NPN Models Remote Programming N O 10 30V dc Load PNP Models Load 10 30 V dc Remote P...

Page 4: ...ton is a 3 way button The positions are engaged by rocking the button left right The SET position is engaged by clicking down the button while the rocker is in the middle position All three button pos...

Page 5: ...1234 Eco 123P diSP 1234 diSP 123P Eco 1234 Eco 123P display flips 180 1234 Gn 8 Fixed Gain Set To scroll through menu lists Press or To enter a choice list or to select and save Click SET To exit a ch...

Page 6: ...ated signal Output OFF Output ON Darkest Taught Condition Lightest Taught Condition Position adjusted by Manual Adjust Figure 2 Two Point TEACH Light Operate shown The Output ON and OFF conditions can...

Page 7: ...shown Output ON and OFF conditions can be reversed using the LO DO switch Light SET Sets a threshold a programmable offset below the presented condition Changes output state on any condition darker t...

Page 8: ...presented and the sensor positions a threshold exactly at the presented condition When a condition lighter than the threshold is sensed the output either turns ON or OFF depending on the LO DO setting...

Page 9: ...IL without Offset Presented condition cannot be used for the SET method Threshold Alert or Threshold Error Severe contamination changes in the taught condition can prevent the Auto Thresholds algorith...

Page 10: ...ect or 150 mm 6 in cable with a 4 pin M12 Euro style quick disconnect or 150 mm 6 in cable with a 4 pin M8 Pico style quick disconnect Environmental Rating IEC IP50 NEMA 1 Operating Conditions Tempera...

Reviews: