E-Stop Safety Module
– Models ES-GA-5A and ES-HA-5A
45.0 mm
(1.77")
110.0 mm
(4.33")
75.0 mm
(2.95")
DIN Mounting
Tab (Supplied)
35.0 mm
(1.38")
DIN Mounting Slot
B2 S31 14 24 34 44 52
S32
A2
S33 S32 S35 S21 S22
S11
A1
S12Y30
Y31Y32
Y35
S34
B1
13
23
33
43
51
Figure 5. Model ES-..A-5A E-Stop Safety Module enclosure dimensions
CAUTION ...
Abuse of
Module After Failure
If an internal fault has
occurred and the ES-...A-5A will not reset,
do
not tap, strike, or otherwise attempt to
correct the fault by a physical impact to the
housing.
An internal relay may have failed in
such a manner that its replacement is
required.
If the Module is not immediately replaced
or repaired, multiple simultaneous failures
may accumulate such that the safety
function can not be guaranteed.
!
Repairs
NOTE: Do not attempt any repairs to the ES-..A-5A Emergency Stop Safety Module. It
contains no field-replaceable components. Return the Safety Module to the
factory for warranty repair or replacement.
If it ever becomes necessary to return an E-Stop Safety Module to the factory, please
do the following:
1) Contact the Banner Factory Application Engineering Group at the address or at the
numbers listed at the bottom of the back page. They will attempt to troubleshoot
the system from your description of the problem. If they conclude that a
component is defective, they will issue an RMA (Return Merchandise
Authorization) number for your paperwork, and give you the proper shipping
address.
2) Pack the E-Stop Safety Module carefully. Damage which occurs in return shipping
is not covered by warranty.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: [email protected]