 Setting up the Network    7

BeoPlay V1 (Bedroom)

LINK TO OTHER PRODUCTS

: Select BeoLink Converter NL/ML (Select the product to be distributed from. In this setup the sources are distributed 

from the Audio Master (BeoMaster5) via the BeoLink Converter NL/ML).

 -   

IS BeoLink Converter NL/ML IN THE SAME ROOM AS THIS TELEVISION?

: Select NO. (Select whether or not the Audio Master (BeoMaster5) 

and not the BeoLink Converter NL/ML is in the same room as the TV).

VM OPTION

: Select option 2. (This setting is only relevant for Beo4 remote).

!  Network Link products connected to the BeoLink Converter NL/ML must be switched on to make it possible for the BeoLink Converter NL/ML to 

detect them automatically. Master Link sources that are not present in the system has to be removed manually in the 

Configuration

 menu under 

Experience mapped to NL

.

!  The NL/ML Delay Box is optional. Mount a NL/ML Delay Box for echo free audio source distribution.

Setting up the Network

Network Link 

An extra router (Network Link router) is recommended for the Network Link as it needs it’s own subnet.
The WAN port on the Network Link router must be connected to a LAN port on the ISP router with a CAT7 cable. This is done to avoid that data 

traffic meant for the 1st subnet will interfere with data traffic on the 2nd subnet.

The Bang & Olufsen products can be connected to any of the LAN ports on the Network Link router. Each of the four ports on the Network Link 
router can be extended with a switch recommended by Bang & Olufsen.

Access the Network Link router

In order for the Network Link router to work when connected to the existing network, it must be configured with a different address range than 

the ISP router on the network.

-  Connect a PC to the Network Link router and enter the default IP-address 192.168.1.1 in the address field in the Web browser on the PC.

-  Enter User Name: 

admin

 and Password: 

admin

. (If a Network Link router is already installed the User name and Password might be changed).

Set up a Bang & Olufsen sub-network

-  Access the Network Link router
-  Go to 

Basic Setup

 screen, 

Network Setup

 and 

Router Address

.

-  Enter the IP address to 192.168.100.1 and save the settings

The Bang & Olufsen sub-network has now been setup. All devices connected to this sub-network must have the IP address 192.168.100.XXX.
The last three digits in the IP address are unique.

Summary of Contents for BeoLink Converter NL/ML

Page 1: ...BeoLink Converter NL ML Type 1790 Installation Guide English version 1 4 37 2 17 0 4 0...

Page 2: ...s guide When the guide is opened it automatically opens in Full Screen Mode can be left as desired see below This is primarily done to optimise the usability of screen reading There are several ways t...

Page 3: ...made by Bang Olufsen certified installers only Introduction Setting up NL ML Delay Box Installation Option settings Delay overview Setting up the BeoLink Converter NL ML DHCP setting Access the web in...

Page 4: ...use The connections in the RJ45 socket and the ML socket are identical The RJ45 socket is used if the Master Link cable is equipped with a RJ45 plug The ML socket is used if the Master Link cable is e...

Page 5: ...onfiguration Critical error for instance no communication with the H8 microcomputer or an application error Normal operation streaming Normal operation no streaming Flash updating peripherals Solid Fl...

Page 6: ...ng menu in the TV SETUP PRODUCT INTEGRATION BeoVision 11 Living room LINK TO OTHER PRODUCTS Select BeoLink Converter NL ML Select the product to be distributed from In this setup the sources are distr...

Page 7: ...ort on the Network Link router must be connected to a LAN port on the ISP router with a CAT7 cable This is done to avoid that data traffic meant for the 1st subnet will interfere with data traffic on...

Page 8: ...ter and check the DHCP Reservation to find the current IP address for the BeoLink Converter NL ML It will be named BLC serial number Leave the DHCP Reservation menu and enter the BeoLink Converter NL...

Page 9: ...e g information about the Service Counters from the BeoLink Converter NL ML Enabling the Usage patterns must be agreed by the owner of the BeoLink Converter NL ML Never switch the BeoLink Converter N...

Page 10: ...in the drop down boxes In this case one of the products must be chosen to communicate with the BeoLink Converter NL ML PowerLink Default volume can be changed in a range between 0 60 Line in sense Ena...

Page 11: ...This can be done in the drop down box Products connected to the Network Link are detected automatically Remember to save the settings Configuration Experience mapped to NL ML Role is V Master Experie...

Page 12: ...o the Network Link are detected automatically Remember to save the settings Configuration Experience mapped to NL ML Role is A Master Experience mapped to NL Sources visible on NL tells the Network Li...

Page 13: ...source Network Link sources connected to the Network Link will be visible in NL source list It is possible to allocate a Network Link source to another Master Link source if required This can be done...

Page 14: ...ience mapped to NL Sources visible on NL tells the Network Link products which Master Link sources should be visible in the source list menu on the Network Link products You can also rename the Master...

Page 15: ...the Network Link will be visible in NL source list It is possible to allocate a Network Link source to another Master Link source if required This can be done in the drop down box Remember to save th...

Page 16: ...ster Link source the BeoLink Converter NL ML has to be selected as an Network Link product IR mapping settings are only relevant if Power Link speakers and IR reciever are installed as in example 1 2...

Page 17: ...n about the NL ML Delay Box see page 18 If using a wireless connection together with the NL ML delay Box then echo will not be eliminated NL products Shows all known products in the network with type...

Page 18: ...overview page 19 to see the correct dip switch settings If ML delay setting is outside the range 341 ms of NL ML Delay Box i e more than 1000 ms then go to the following menu on the BeoLink Converter...

Page 19: ...If other delay values are required according to the ML Delay setting displayed in Network Link supported products then actual dip switch setting can be found from this table Audio delay ms Comments LS...

Page 20: ...n ML enabled is unchecked Share speaker table Question in Network Link TV Living room Other rooms Comments Example 1 IS BeoLink Converter NL ML IN SAME ROOM AS THIS TELEVISION NO NO DO YOU WANT TO USE...

Page 21: ...as the TV DO YOU WANT TO USE THE TV SPEAKERS AS THE ONLY SPEAKERS FOR BeoLink Converter NL ML YES Select whether or not the TV speakers should be shared and used as the only speakers for the Audio Mas...

Page 22: ...USE THE TV SPEAKERS AS THE ONLY SPEAKERS FOR BeoLink Converter NL ML YES Select whether or not the TV speakers should be shared and used as the only speakers for the Audio Master BeoMaster5 BeoLink C...

Page 23: ...Link Converter NL ML NO Select whether or not the TV speakers should be shared and used as the only speakers for the Audio Master BeoMaster5 BeoLink Converter NL ML connect to table BLC Primary Second...

Page 24: ...mary Secondary Comments Example 4 BLC Library BV11 BLC Living room To Power Link Video sources from living room BV11 Audio sources from living room BS5 AUX line in from local product To Network Link A...

Page 25: ...ving room Master TV BV12 share speakers with Audio Master BeoMaster 5 because of BLC primary settings DO YOU WANT TO USE THE TV SPEAKERS AS THE ONLY SPEAKERS FOR BeoLink Converter NL ML BeoLink Conver...

Page 26: ...Audio Master BeoSound Moment because of BLC primary settings DO YOU WANT TO USE THE TV SPEAKERS AS THE ONLY SPEAKERS FOR BeoLink Converter NL ML BeoLink Converter NL ML connect to table BLC Primary S...

Page 27: ...k TV Living room Other rooms Comments Example 7 IS BeoLink Converter NL ML IN SAME ROOM AS THIS TELEVISION NO Select whether or not the Audio Master in this setup no Audio Master and not the BeoLink C...

Page 28: ...room Master TV BV12 share speakers with Audio Master BeoSound 4 because of BLC primary settings DO YOU WANT TO USE THE TV SPEAKERS AS THE ONLY SPEAKERS FOR BeoLink Converter NL ML BeoLink Converter NL...

Page 29: ...an iPhone iPad see page 8 Access the BeoLink Converter NL ML with the default username admin and password admin The setup app for smartphones tablets can also be used Go to the menu Configuration Set...

Page 30: ...ve is unnecessary if the integration is set in the Connect to primary menu in the BeoLink Converter NL ML previous Set up the Bedroom TV BeoPlay V1 Turn on the TV and go to the PRODUCT INTERGRATION me...

Page 31: ...same way as on an iPhone iPad see page 8 Access the BeoLink Converter NL ML with the default username admin and password admin The setup app for smartphones tablets can also be used Go to the menu Co...

Page 32: ...nt for Beo4 remote Set up the kitchen TV BeoVision 7 Select option 6 in BeoVision 7 Set up the office product BeoLink Active Select option 6 in BeoLink Active Conclusion In the living room it is possi...

Page 33: ...info Hardware information about the Small Enigne HWD PCB version Variant BOM Bill Of Material version Configuration word Info Project Info The project info can be used to keep information about the p...

Page 34: ...Engine H8 Software version of the software for the H8 microprocessor FEP Software version of the software for the Front End Processor Info Service Counters The Service Counters gives information about...

Page 35: ...the DHCP range If the DHCP is disabled in the router the IP address must be set up manually in the Network Menu The first three octets in the IP address must be the same digits as in the router The s...

Page 36: ...new messages appear System log is cleared after reboot Remember to save the log before rebooting in case of a problem Tools Report If a malfunction occurs in the BeoLink Converter NL ML it is possibl...

Page 37: ...to detect the BeoLink NL ML Converter automatically It is also possible to enter the IP address 169 254 11 22 and make a manual connection to BeoLink NL ML Converter The ServiceTool contains the foll...

Page 38: ...ndicator flashes first time 1 A Slave Audio Slave Within 3 seconds ML Role seen from Master Link side 2 A Master Audio Master Within 3 seconds ML Role seen from Master Link side 3 V Master Video Maste...

Page 39: ...in the different ML Roles ML source shows a list of available sources on Master Link retrieved from Network Link The greyed out sources are not available on the Master Link due to the ML role Fig 3 sh...

Page 40: ...e A Master is present on the Master Link then the BeoLink Converter NL ML can distribute any source from Master Link to Network Link In the BeoLink Converter NL ML menu Experience maped to NL all sour...

Page 41: ...er Link then the BeoLink Converter NL ML can t distribute sound from any video source from Master Link to Network Link In the BeoLink Converter NL NL menu Experience maped to NL no video sources can b...

Page 42: ...e fig 11 As BeoMaster BeoSound 5 the A Master is removed from the Master Link then the BeoLink Converter NL ML can t distribute sound from any audio source from Master Link to Network Link In the BeoL...

Page 43: ...ibute anything from Master Link to Network Link In the BeoLink Converter NL NL menu Experience maped to NL no sources can be selected at all See fig 15 Be aware of that it is necessary to have a ML Po...

Page 44: ...m these sources from Master Link to Network Link In the BeoLink Converter NL NL menu Experience maped to NL N MUSIC and N RADIO can t be selected See fig 18 Be aware of that in some situations there w...

Page 45: ...14 Experience mapped to NL ML Role is A Slave 14 Sources visible on ML ML Role is Source Center 15 Experience mapped to NL ML Role is Source Center 15 IR mapping Home Automation 16 NL management Back...

Reviews: