Technical data
Panel PC 2100 user's manual V1.17
179
Model number
5ACCIF01.FPLS-000
Electrical characteristics
Power consumption
1.5 W
Operating conditions
Pollution degree per EN 61131-2
Pollution degree 2
Environmental conditions
Temperature
Operation
-20 to 55°C
Storage
-20 to 60°C
Transport
-20 to 60°C
Relative humidity
Operation
5 to 90%, non-condensing
Storage
5 to 95%, non-condensing
Transport
5 to 95%, non-condensing
Mechanical characteristics
Weight
25 g
Table 156: 5ACCIF01.FPLS-000 - Technical data
1)
Yes, although applies only if all components installed in the complete system have this certification and the complete system bears the corresponding mark.
2)
Yes, although applies only if all components installed in the complete system have this certification and are listed on the associated DNV GL certificate for
the product family.
3)
For more information, see Automation Help (Communication - POWERLINK - General information - Hardware - IF / LS).
2.3.5.4.3.1 POWERLINK interface - Pinout
The POWERLINK interface on the system unit is referred to as IF1.
POWERLINK - IF1
1)2)
Wiring
S/STP (Cat 5e)
Cable length
Max. 100 m (min. Cat 5e)
Status LED
On
Off
Green
See Status/Error LED.
Link LED
On
Off
Yellow
Link (POWERLINK net-
work connection available)
Activity (blinks to indi-
cate active data transfer)
RJ45, female
1
LED "Status"
LED "Link"
Table 157: 5ACCIF01.FPLS-000 - POWERLINK interface
1)
The interfaces, etc. available on the device or module have been numbered as such for the purpose of clear differentiation. This numbering may deviate
from the numbering used by the respective operating system, however.
2)
This interface is referred to as IF1 in Automation Studio / Automation Runtime.
2.3.5.4.3.2 COMA serial interface - Pinout
Serial interface COMA is referred to as IFx on the system unit.
Serial interfaceCOM A - IFx
1)2)3)
RS232
Type
RS232, modem supported, not electrically isolated
UART
16550-compatible, 16-byte FIFO
Transfer rate
Max. 115 kbit/s
Bus length
Max. 15 m
Pin
Assignment
1
DCD
2
DSR
3
RXD
4
RTS
5
TXD
6
CTS
7
DTR
8
RI
9
GND
10
GND
10-pin, male
1 3 5 7
2 4 6 8 10
9
Table 158: 5ACCIF01.FPLS-000 - Interface COMA
1)
The interfaces, etc. available on the device or module have been numbered as such for the purpose of clear differentiation. This numbering may deviate
from the numbering used by the respective operating system, however.
2)
This interface (if available) is enabled automatically in BIOS as COMA with default I/O address 3F8h and IRQ 4.
3)
This interface is referred to as IF5 in Automation Studio / Automation Runtime.