Commissioning • Installation
46
Power Panel T30 User's manual V1.42 - Translation of the original documentation
4.1.4 Mounting orientations
Important!
Possible damage to device!
•
An ambient temperature that is too high can cause damage to the device or faulty behavior.
•
For the maximum permissible ambient temperature, see the technical data for the respective
device.
The following diagrams show the permissible mounting orientations of Power Panels. The operating temperature
limit values specified in the technical data apply taking into account the permissible mounting orientations.
Tilted mounting orientation
25°
25°
Rotated mounting orientation
The Power Panel is permitted to be rotated in 90° increments and installed.
90°
270° (-90°)
180°
0°
Additional mounting orientations
If the Power Panel is used in mounting orientations other than those indicated above, the application must monitor
the temperature and take appropriate measures in the event of overtemperature.