Device description • Power Panel T30 - 10.1" variants
Power Panel T30 User's manual V1.42 - Translation of the original documentation
35
Model number
6PPT30.101G-20W
6PPT30.101G-20B
6PPT30.101N-20W
6PPT30.101N-20B
Operating conditions
Permissible mounting orientations
Standard mounting orientation
Vertical
Tilt
±25°
Rotation
In 90° increments (portrait/landscape)
Installation elevation above sea level
0 to 2000 m
No limitations
>2000 m
Reduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529
Front: IP65, Back: IP20
Environmental conditions
Temperature
Operation
-20 to 60°C
Storage
-20 to 70°C
Transport
-20 to 70°C
Relative humidity
See temperature/humidity diagram.
Mechanical properties
Front
Design
Aluminum white pinstripe
Anthracite gray pinstripe
Aluminum white pinstripe
Anthracite gray pinstripe
Dimensions
Width
276 mm
172 mm
Height
172 mm
276 mm
Depth
47.8 mm
Weight
0.9 kg
Table: Power Panel T30 - 10.1" variants - Technical data
1)
The clock frequency is 600 MHz for hardware revisions less than C0.
2)
The current-carrying capacity is 0.1 A for hardware revisions less than B0.
3)
The current-carrying capacity is 0.1 A for hardware revisions B0 to B2.
The current-carrying capacity is 0.5 A for hardware revisions less than B0.
4)
Value applies at an ambient temperature of 25°C. Reducing the brightness by 50% can increase the half-brightness time up to 50%.
5)
The internal fuse cannot be replaced by the user or reset.
3.6.4 Temperature/Humidity diagram
Temperature [°C]
Relative humidity [%RH] (non-condensing)
0
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90
95
100
-80 -70 -60 -50 -40 -30 -20 -10
0
10
20
30
40
50
60
70
80
90
Storage
Transport
Storage
Transport
Operation
Operation
Figure: Power Panel T30 - 10.1" variants - Temperature/Humidity diagram