Software
82
Mobile Panel 40/50 User's manual V1.80
4.2 B&R
Automation
Device
Interface
(ADI)
Control
Center
The
Automation
Device
Interface
(ADI) allows access to specific functions of B&R devices. The settings of these
devices
can
be read out and changed in Windows using the B&R
Control
Center in the
Control
Panel.
Figure 59: B&R
Control
Center screenshots - Examples
Information:
The displayed temperature and voltage values (e.g.
CPU
temperature, core voltage, battery voltage)
represent uncalibrated information values. No conclusions about possible alarms or hardware mal-
functions
can
be drawn from this. The hardware components used have automatic diagnostic func-
tions in the event of error.
4.2.1 Functions
Information:
The functions available in the
Control
Center depend on the
device
family.
•
Changing display-specific parameters
•
Reading out
device
-specific keys
•
Updating the key configuration
•
Testing keys or
device
-specific
LED
s of a membrane keypad
•
Reading out or calibrating
control
devices (e.g. key
switch
, handwheel, joystick, potentiometer)
•
Reading out temperatures, fan speeds,
switch
positions and statistical data
•
Reading out operating hours (power-on hours)
•
Reading user settings and factory settings
•
Reading
software
versions
•
Updating and backing up
BIOS
and
firmware
•
Creating reports for the current system (support)
•
Setting the SDL equalizer value for the SDL cable adjustment
•
Changing the user serial ID
Depending on the version, a detailed description of the
Control
Center is available either in the integrated help
documentation or in the user documentation.