Accessories
Mobile Panel 40/50 User's manual V1.80
119
Model number
5CAMPB.0100-10
Outer jacket
Material
Flame-retardant PUR
Color
Similar to RAL 7012
Cable elements
Control
devices
Direct connection between
control
devices and monitoring
device
(6 wires)
CAN
2 pairs with shielding (5 wires)
Ethernet
Twisted pair
cable for
Ethernet
(10/100 Mbit/s) (4 wires, male RJ45 connector)
Series
3 wires
Power supply
+24 VDC supply voltage and grounding (3 wires), SELV
1)
Enable
switch
Direct connection between enable
switch
and monitoring
device
(6 wires)
Connector
Type
FA. Jacob GmbH type: PERFECT 50.620 M
Electrical characteristics
Conductor resistance
≤140 Ω/km (0.15 mm² conductor)
≤27 Ω/km (0.75 mm² conductor)
Insulation resistance
≤500 Ω/km
Operating conditions
Flame-retardant
Per
IEC
60332-1 and VW1 / FT1 in accordance with C-UL
Shield attenuation
Per
IEC
60096-1, Amendment 2
Oil and hydrolysis resistance
Per
VDE
0282-10
Environmental conditions
Temperature
Moving
-20 to 60°C
Static
-20 to 80°C
Mechanical characteristics
Dimensions
Length
10 m ±20 cm
Diameter
10 mm
Bend radius
Moving
60 mm
Fixed installation
30 mm
Weight
160 g/m
Tension
Max. 140 N
Table 69: 5CAMPB.0100-10 - Technical data
1)
EN
60950 requirements must be observed; see section "+24 VDC power supply" of the user's manual.
6.5.1.4 Cable pinout
ST3
CAN 1 & CAN 2
ST1
Power supply
+ grounding
ST5
Emergency stop
ST4
RS232
ST7
Enable switch
ST2 -
Ethernet
M3 cable lug
RJ45
ST6
Key switch
or pushbutton
60 mm
60 mm
70 mm
70 mm
50 mm
50 mm
55 mm
80 mm
50 mm
250 mm
RJ45
Ethernet
3 wires
RS232
6 wires
Control devices
6 wires
Enable switch
5 wires
CAN 1 & CAN 2
3 wires
Power supply
+ grounding
RJ45
Control cabinet side
Connection box side
Cable gland
Figure 82: 5CAMPB.0xxx-10 - Cable pinout