8 |
Connecting the display |
ZM Series User Manual
Connecting power
3 4
2
1
1 2
3 4
5
6
+
-
1
Yellow Wire - power control
2
Blue wire - chassis ground
3
Red wire - positive DC supply (12V or 24V system)
4
Black wire - negative DC supply (12V or 24V system)
5
Fuse - see table at end of section
6
DC supply
¼
Note:
this display is not intended for use vessels fitted with a positive ground electrical
system. The power input cable screen drain wire should be connected to a negative ground.
¼
Note:
chassis ground will typically not be required. In certain problematic installations it may
help stabilize touch screen sensitivity, ie. prevent ‘false’ touches, or non-registered touches.
Recommended fuse rating
Model
ZM16-T
ZM19-T
Fuse
3 amp
4 amp