network. Multi-source mode should be selected if no legacy echosounder is connected
to the network.
Ú
Note:
When changing the mode to multi-source you must wait 30 seconds and then
power down all sources for. Wait 1 minute, then restart all connected sources.
Structure depth offset
All transducers measure water depth from the transducer to the bottom. As a result, water
depth readings do not account for the distance from the transducer to the lowest point of
the boat in the water or from the transducer to the water surface.
B
A
B
A
•
To show the depth from the lowest point of the vessel to the bottom, set the offset equal
to the vertical distance between the transducer and the lowest part of the vessel,
A
(negative value).
•
To show the depth from the water surface to the bottom, set the offset equal to the
vertical distance between the transducer and the water surface,
B
(positive value)
•
For depth below transducer, set the offset to 0.
Use network depth and temp data
Selects from which network source depth and temperature data is shared on the NMEA 2000
network.
Installation
Use this dialog to setup and configure available sources.
Source
Select this option to display a list of sources available for setup. The settings you make in the
rest of the dialog pertain to the source selected.
Source name
Select this option to set a descriptive name for the selected transducer.
32
System setup
| Zeus³S Installation Manual