Manual source selection
Manual selection is generally only required where there is more than one source for the same
data, and the automatically selected source is not the one desired.
Group source selection
Multifunction displays, autopilot controllers, and instruments have the ability to:
•
Use data sources (for example position, wind direction, and so on) that all other products
on the network use, or alternatively use a data source independently from other units.
•
Globally change all displays over to a different source from any display. (This only includes
products set to Group mode.)
Ú
Note:
In order to enable group selection, the display must be set to Default group.
Devices with the Group set to None can be set to use different sources to those of the rest of
the network devices.
Advanced source selection
This allows the most flexible and precise manual control over which devices provide data.
Some data sources, such as those for fuel level, or engine RPM, can only be changed from the
Advanced menu. Occasionally Auto Select may not assign the desired source, which may be
corrected using the Advanced Source Selection. An example of this is where twin
installations with NMEA 2000 compliant engines are not programmed with unique instance
numbers. This means that the auto select feature cannot determine which engine is fitted on
the port and which is fitted on the starboard side.
Ú
Note:
The Advanced option is visible in multiple places - the bottom of the Sources list,
and under each source category (for example, Compass). The latter shows a filtered list
that only relates to devices that output data relevant to the category.
Device list
The Device list shows the devices that provide data. This may include a module inside the
unit, or any external NMEA 2000 device.
Selecting a device in this list will bring up additional details and options for the device.
All devices allow allocation of an instance number in the Configure option. Set unique
instance numbers on any identical devices on the network to allow for the unit to distinguish
between them. The Data option shows all data being output by the device. Some devices
will show additional options specific to the device.
Ú
Note:
Setting the instance number on a 3rd party product is typically not possible.
Diagnostics
Provides information useful for identifying an issue with the network.