![B&G H5000 Pilot Installation Manual Download Page 33](http://html.mh-extra.com/html/bandg/h5000-pilot/h5000-pilot_installation-manual_460130033.webp)
|
33
Expansion Modules |
H5000 Installation
Expansion Modules
1:
Find a suitable location for the module.
Mount the module vertically. Ensure that there is at least 100 mm
clearance between the connector and grommet and any surface to
enable easy access to cables
2:
Mark the hole positions, drill pilot holes and fi x into position with
two self tapping screws
3:
To remove the lid, unscrew the
two lid screws.
Note:
The lid hinges at the
bottom edge of the module. To
close the lid you need to locate
the bottom edge fi rst.
4:
Cut the grommet indicated to
a length that creates a tight fi t
for the cable to be fed. Feed the
cable through and wire into the
module plug.
Ensure the cables are positioned
to the left of the centre pillar
and the plug can reach the
connectors without placing
tension on the wires.
6