background image

23656a GB/2019-06

valid for: 
Filtration FA 16 and FA 40 with 

fi

 lter aggregate FA 610

Filtration FA 75, FA 110, FA 180, FA 210, FA 220 and FA 320 with 

fi

 lter aggregate FA 620

3 4

Filtration FA

Operating Manual

Translation of Operating Manual 

Summary of Contents for Sonorex Technik

Page 1: ...valid for Filtration FA 16 and FA 40 with filter aggregate FA 610 Filtration FA 75 FA 110 FA 180 FA 210 FA 220 and FA 320 with filter aggregate FA 620 3 4 Filtration FA Operating Manual Translation of...

Page 2: ...slation and the original of this document the original version will take precedence BANDELIN accepts no responsibility or liability for damage caused by improper handling or usage contrary to the inte...

Page 3: ...ufacturer assumes no responsibility for safety or the proper functioning of the device in the event of improper handling or a use other than the intended use In the event of unauthorised alterations m...

Page 4: ...5 Warnings and safety instructions 10 2 Preparation 11 2 1 Scope of delivery 11 2 2 Assembly Installation 11 2 2 1 Connecting the FA 16 FA 40 or FA 75 12 2 2 2 Connecting the FA 110 FA 180 or FA 210...

Page 5: ...Troubleshooting 18 6 2 1 Replacing fuses 19 6 3 Customer service 19 6 3 1 Repairs and service 19 6 3 2 Decontamination certificate 20 7 Consumable materials 20 8 Decommissioning 20 Informative annexes...

Page 6: ...plate on the back A filtration is comprised of a filter aggregate and a corresponding connection set The filter aggregate is available in two sizes FA 610 and FA 620 depending on the bath volume to b...

Page 7: ...d purpose Existing SONOREX TECHNIK RM TM ultrasonic baths do not require conversion before being equipped with a filtration The filtration serves to filter aqueous cleaning agents in bath temperatures...

Page 8: ...ent consumption 1 76 A Fuse 1 T 2 5 A Pre filter Housing PP Filter cartridge Nylon weave tray insert atop a filter element fineness of filtration 350 m reusable Filter cartridge size FA 610 9 FA 620 2...

Page 9: ...PF EPDM hoses Brass hose sockets galvanically coated Stainless steel return flow pipe More detailed information on the IP 55 protection class pursuant to DIN EN 60529 Ambient conditions pursuant to EN...

Page 10: ...ing agents such as acids and chemicals that for example contain or separate chlorine ions such as certain disinfectants washing up liquids household cleaners or saline solutions Do not expose the filt...

Page 11: ...onditions 2 1 Scope of delivery 1 Filter aggregate see delivery note 1 Connection set APF 1 Operating Manual Additional accessories as ordered see delivery note The specific filter aggregate and conne...

Page 12: ...s Connecting the tank inlet with the pressure side of the filter aggregate 1 Screw the hose socket to the fine filter ball valve 2 Slide the hose ends onto the hose sockets return flow and fine filter...

Page 13: ...amps Connecting the tank inlet with the pressure side of the filter aggregate 1 Screw the hose socket to the fine filter ball valve 2 Slide the hose ends onto the hose sockets return flow and fine fil...

Page 14: ...ose ends onto the hose sockets and secure using hose clamps Connecting the tank inlet with the pressure side of the filter aggregate 1 Screw the hose socket to the fine filter ball valve 2 Slide the h...

Page 15: ...er aggregate The green indicator light is continuously illuminated during operation Check the fill level in the ultrasonic bath multiple times and refill if necessary Make sure that liquid is continuo...

Page 16: ...Preparation Open the 3 way ball valve on the connected ultrasonic bath Open the ball valve on the filter aggregate Step 2 Switching on Press the On button green to switch on the filter aggregate Use t...

Page 17: ...wipe dry 5 2 Storage If not used for longer periods of time empty the filter aggregate completely and store it covered in a cool dry place 6 Maintenance and repair 6 1 Maintenance Keep the filter aggr...

Page 18: ...f 6 2 Troubleshooting SONOREX TECHNIK filter aggregates are robust constructions designed to offer maximum reliability Nevertheless the possibility of a malfunction due to a defective component can ne...

Page 19: ...sted under Technical Data see Chapter 1 4 Reassemble the control box by following the above instructions in reverse Reconnect the power cable Re open the ball valves 6 3 Customer service If service is...

Page 20: ...our employees The form can be downloaded from our website as a PDF file www bandelin com Downloads 7 Consumable materials Filter cartridges Type Description Order No EF 1025 10 fine filter 9 25 m 238...

Page 21: ......

Page 22: ...a filter aggregate note that they can only be operated in alternation Switch the three way ball valve accordingly Overflow gutter Return flow hose clamped to the tank edge Information on flow directio...

Page 23: ...ank edge and the return flow from the oil separator is via the sprinkle tube The two accessory devices may be operated simultaneously Return flow hose clamped to the tank edge Inlet Oil overflow Filte...

Page 24: ...Note The enclosed CD contains the Operating Manual in this language and other languages as well as additional information...