12. Setting Limits

12.1 Set the Limit Positions and adjust drive speed:

When setting the Close limit, ensure the position is when the door 

makes first contact with the ground. Alternatively for the Open limit 

the position should be at the height of the garage opening.

NOTE:

 The drive speed is set to the fastest setting by default. This 

may not be suitable for larger doors or for single piece doors. For tilt 

doors (J-Type only), please refer to Appendix F for initial setup. 

a. Switch power on and the BLUE LED on the CLOSE button 

 

will start to flash and the GEAR  

 LED is lit to indicate that the 

opener is ready to set the Close travel limit.

b. Press either the CLOSE  

 or OPEN button to move the door to 

the halfway point. 

WARNING! In setting the close limit position, 

do not force the door into the floor with 

excessive force, as this can interfere with 

the ease of operation of the manual release 

mechanism.

Door Opener 

Speed Mode

STATUS

MAIN LIGHT

Fast (Default)

On

3 Flash

Medium 

On

2 Flashes

Slow

On

1 Flashes

WARNING! The door will automatically close, 

open and close again after the next step. 

Ensure that nothing is in the door’s path.

NOTE: If unhappy with the speed or travel limit setting, 

restart this procedure by resetting the door limit positions 

as per below first.

12.2 Clearing the Door Limit Positions

Limit positions can be deleted by:

a. Press the MODE button repetitively until the GEAR  

 

LED is lit.

b. Press and hold the MODE button for 10 secs, let the 

MODE button go when the main light stops flashing.

c. The close LED will flash continuously to indicate limits 

have been cleared.

NOTE: If no action is taken within 30 seconds, the opener 

will return to normal operating mode and restore the 

original settings.

d. Follow from CLOSE limit: above to set new limit 

positions, remembering to reset the tracklock.

CLOSE limit:  

i.  Press and hold the CLOSE button 

 to start closing 

the door, taking note of the speed the door moves. 

ii.  If the close speed is not suitable, to make a change, 

press and hold  the CLOSE button and by pressing 

the STOP / SET button on the opener it will cycle 

through all three speed modes as shown in table.

iii. Once at the desired speed, release the CLOSE 

button. 

iv. To set the close limit, inch the door by making single 

presses of the CLOSE button 

 to the desired 

position. We recommend the CLOSE limit position 

being the first point of contact of the rubber strip  

(at the bottom of the door) with the ground.

v.  If the door overshoots, press the OPEN button 

 to 

move the door in the OPEN direction.

vi. When the door is at the desired CLOSE position, press 

the STOP / SET button on the opener, the GREEN LED 

on the OPEN button  

 will now flash.

OPEN limit:  

i.  Press and hold the OPEN button 

  to start opening 

the door, taking note of the speed the door moves. 

ii.  If the open speed is not suitable, to make a change, 

press and hold  the OPEN button and by pressing 

the STOP / SET button on the opener it will cycle 

through all three speed modes as shown in table.

iii. Once at the desired speed, release the OPEN button. 

iv. Continue inching the door to the desired position. 

v.  To set the open limit, inch the door by making 

single presses of the OPEN button 

 to the desired 

position. We recommend the OPEN limit position 

being the height of the garage opening.

vi. If the door overshoots, press the CLOSE button 

 to 

move the door in the CLOSE direction.

vii. When the door is at the desired OPEN position, press 

the STOP / SET button The door will now automatically 

close and open to calculate the safety obstruction 

settings.

12.3 Re-profiling the Door

Re-profiling is a simplified way of re-learning the travel 

characteristic of a previously setup Limit Switch travel 

installation. Re-profiling can be used when the travel 

characteristics of the door change due to mechanical 

adjustments etc. To initiate a re-profile:

a. Limits must be set.

b. Press the MODE button repetitively until the GEAR  

 

LED is lit.

c. Press and hold the CLOSE button 

 for two seconds, 

the door will open and close by itself to record profile.

Refer to Appendix B & C for adjustments 

to margins.

tip

Summary of Contents for PanelMax SDO-8

Page 1: ... Door Opener installation instructions PanelMax These instructions are intended for professional garage door opener installers All references are taken from inside looking out DOC 161060_03 RELEASED 16 06 20 PanelMax TM SDO 8 ...

Page 2: ...mode position 22 F Setting up Tilt Door 23 Home Owner Instructions WARNING IMPORTANT SAFETY INSTRUCTIONS FOLLOW ALL INSTRUCTIONS SINCE INCORRECT INSTALLATION CAN LEAD TO SEVERE INJURY before installing the drive remove all unnecessary ropes or chains and disable any equipment such as locks not needed for powered operation before installing the drive check that the door is in good mechanical condit...

Page 3: ... Practice correct lifiting techniques when required to lift the door as per installation instructions Fall from ladder Ensure ladder is the correct type for job Ensure ladder is on flat firm ground that will take the weight without the legs sinking Ensure user has 3 points of contact while on ladder Crush injury from unsecured door Place a 2 metre exclusion zone around area under the door while it...

Page 4: ...orce required to move the door should not exceed 20kg d Lift the door to about halfway When released the door should stay in place 2 1 Examine the conditions in the garage a Look at the ceiling i Is it plastered The opener is mounted to a perforated angle which MUST be securely fastened to a structural support You will need to locate the structural beams in the ceiling which are generally 400mm ap...

Page 5: ... x Track Bracket 16 1 x Pre Assembled track 10 00 min MINIMUM HEAD ROOM FOR STEEL RAIL 57mm DOORS HIGHEST POINT 210m m 3198mm 3330mm 157mm 295mm Rail no Extension Kit 3198mm Rail 1 Extension Kit 3988mm Rail 2 Extension Kits 4778mm Rail refers to 3160 rail 15 1 16 5 4 6 7 12 8 14 11 9 13 10 5 Position Perforated Angle The Opener a MUST BE installed in a dry position protected from weather b REQUIRE...

Page 6: ...failure may ensue causing serious personal injury and or property damage DO NOT DO IT YOURSELF If sufficient structural support can not be found contact a door profressional for installation DIY c Using step ladder and a level transfer this height to the wall above the door and mark a line 60mm above it across the centre line 7 2 Mounting the Wall Bracket a Draw two lines extending 21 5mm from eac...

Page 7: ...the door requires 2 x perforated L shape metal strips and 2 x shorter perforate L shape metal drop down strips Not supplied 9 Mounting Brackets and Arms 9 1 Mounting the Door Bracket a The door bracket locator 7 is placed over the door bracket 8 on the door s centre line one third down the top panel and mounted using M6 or equivalent screws not supplied b STEEL DOORS ONLY Bracket can be welded in ...

Page 8: ... range 230V 240Va c Rated frequency 50Hz 60Hz Rated power input 235W Door opening Maximum Door Area Maximum Door Weight Door must be well balanced and able to be operated by hand as per warranty conditions and AS NZS 4505 2012 15m2 140kg Minimum headroom 57mm Rated Operating Time 4 mins Rated Temp 5 o C to 40 o C Short Term Peak force 700N Door travel speed mm sec 180mm Rated load 400N Nominal for...

Page 9: ...eed the door moves ii If the close speed is not suitable to make a change press and hold the CLOSE button and by pressing the STOP SET button on the opener it will cycle through all three speed modes as shown in table iii Once at the desired speed release the CLOSE button iv To set the close limit inch the door by making single presses of the CLOSE button to the desired position We recommend the C...

Page 10: ...e the door b Press the transmitter button again to open the door c When the door reaches approximately half way firmly grab the door s bottom rail the door should stop If the door does not reverse readily when closing or stop when opening put the door into manual by pulling down on the manual release string to diesengage the motor and contact 13 62 63 for support 13 3 Test the Manual Door Operatio...

Page 11: ... this mode the timer starts counting down only when the safety beam is triggered ie car leaving the garage To enable the Auto Close function a Press the MODE button repetitively until the GEAR LED starts flashing b Press the OPEN button until the GEAR LED flashes i two 2 times to get to PE auto close or ii three 3 times to get to standard auto close c Press STOP SET button to enter parameter d The...

Page 12: ...LD Open HOLD Light HOLD HOLD Vacation Mode HOLD HOLD The button coded for open only function can close the door if you hold the button for 4 seconds when the door is fully open MAIN LIGHT TRANSMITTER STATUS ON Button added OFF Button removed 2 FLASHES then OFF Remote control deleted 4 FLASHES then OFF Memory full 15 2 Installation of the Wall Mounted Transmitter a Store the transmitter code as per...

Page 13: ...ge door balanced Sticking or binding doors must be repaired Garage doors door springs brackets and their hardware are under extreme tension and can cause serious personal injury DO NOT attempt any garage door adjustment DO NOT use if repair or adjustment is needed Call for a professional garage door service CAUTION Emergency access If your garage has no pedestrian entrance door an emergency access...

Page 14: ...d transmitter button until your door begins to move usually 2 seconds Make sure you can see the door when you use the transmitter b If you are in a vehicle you should aim the transmitter through your windscreen as shown c Check that the door is fully open or closed before you drive in or away d If you press the transmitter whilst the door is moving the door will stop The next press of the transmit...

Page 15: ...ROW Green Opens the door 5 UP ARROW LED Green Illuminates when the door is open and flashes when the door is open with the auto close timer running obstructed on opening or stopped 6 MODE Yellow Enables Load Diagnostics Mode 7 MODE STATUS LED Yellow Illuminates when in Diagnostics Mode 8 REMOTE CONTROL STATUS LED Red Flashes on remote lockout and flickers on remote control activity 9 ADJUSTMENT LE...

Page 16: ...ditions e g temperature or external interference The battery life is exhausted Position of the transmitter in the motor vehicle Make sure you can see the door when you use the transmitter Check the battery status by pressing a button flashing or no light battery need changing Aim the transmitter through the windscreen The Courtesy light does not work LED has failed Change LED The door reverses for...

Page 17: ...o move the door and suspect beam is faulty enter Safety Beam Emergency Close by pressing and holding a pre coded button on transmitter for more than five seconds and the door will start closing 3 Wireless LOCK battery is low Change LOCK battery 4 Wireless PE battery is low Change PE Battery 5 Wireless LOCK is not unlocked and preventing door moving Check LOCK test by pressing emergency release but...

Page 18: ...or mounting points along with door bolts screws cables and connectors 3 Adjustment of spring tension to limit spring fatigue 4 Adjustment of opener travel limits and force margin to ensure the door opens and closes to specification 5 Assessment and adjustment of safety components and accessories including safety beams Auto Lock and Safe Lock if installed 6 Assessment of the door alignment and the ...

Page 19: ...ht Status table to determine if battery needs replacing Light Status Battery Status Solid OK Flashing Requires replacement No light Requires replacement 21 2 Battery Replacement Use a pen to push the battery down through the side opening to release battery Use finger nails to separate the transmitter casing to expose circuit board Use a non metallic object e g pen to remove the battery Some batter...

Page 20: ...D CLOSED 1 LEDS solid flashing flashing solid solid rapid flashing flashing flashing solid Open Open with Autoclose timer running Opening Obstructed on Open Closed Closing Obstructed on Close Stopped Partial Open MODE LED 3 flashing Load Diagnostics mode REMOTE CONTROL STATUS LED 4 flashing rapid flashing Remote lockout Remote Control Activity 04 01 02 03 ...

Page 21: ...e Press STOP SET button to save the parameter s new value or press MODE to leave the value unchanged f Continue from a above to select another parameter or press MODE to exit adjustment mode The Safety Obstruction Force is calculated automatically during setup Adjusting this is normally only necessitated by environmental conditions such as windy or dusty areas and areas with extreme temperature ch...

Page 22: ...mote to move the door in the OPEN direction vi When the door is at the desired CLOSE position press the SET button 2 the GREEN LED on the OPEN button will now flash Button 1 inch Open Button 2 Set Button 4 inch Close OPEN limit i Using the programmed transmitter press and hold the button 1 to open To inch the door single presses of the button 1 will move the door to desired limit ii While inching ...

Page 23: ...your representative is PanelMax installation instructions F Setting up Tilt Door Prior to limit set up the opener can be set to J Type Tilt Profile This process allows the opener to pre set to J Type settings where the limit is not greater than 1500mm If J Type is selected the speed is customised and cannot be changed a Press the MODE button repetitively until the GEAR LED starts flashing b Press ...

Reviews: