background image

B

5

4

4

A

1

3

4

2

3

2

4

4

1

2

Connect Door Arm to Trolley

A.  Preferred Installation:

Disconnect Trolley by pulling on the red handle and slide towards door.

With door closed connect Straight Door Arm (5) to Trolley (4) with Bolt

(3), secure with Nut (1). Connect Curved Door Arm (2) to Door Bracket

with Bolt (3) Secure with Nut (1). Align Straight and Curved Door Arms

with a 2 hole overlap connect with Bolt (3), secure with Nut (1), If

Straight Door Arm (5) is too long, cut the end of the Door Arm.

B.  Where extra travel distance is required:

With door closed connect Curved Door Arm (2) to Door Bracket 

with Bolt (3), secure with Nut (1). Lift Curved Door Arm (2) to meet

Trolley, connect door arm to Trolley with Bolt (3), secure with Nut (1).

Connect Electric Power

To avoid installation difficulties, do not run the garage door

opener until instructed to do so.

Plug the opener into electric outlets as specified by local wiring codes.

The opener light will turn on when power is connected and remain on

for 2-1/2 minutes.

16

A

B

1

3

1

2

3

1

4

3

2

2

3

3

1

1

5

1

2

3

1

3

4

5

3

1

4

8

5

7

9

6

2

Setting the Force

The Force is programmed to operate most doors, however, if Limits are

not able to be set, or the door reverses during normal operation follow

this procedure: Locate the Program Button (1) on the left side panel of

unit (2). Push the Program Button twice to enter unit into Auto-Force

Adjustment Mode. The green LED will flash slowly. Activate unit with

remote and run the unit to the Open Limit. Activate unit again to run the

unit to the Closed Limit. The door must travel through a complete cycle

up and down in order for the Force to be set properly. If the unit stops

before it reaches the Open or Close Limit repeat the process. The

green LED will stop flashing when the Force has been learnt.

18

1

2

Test the Safety Reverse System

The safety reverse system test is important. Garage door must

reverse on contact with a 40mm obstacle laid flat on the floor.

Failure to properly adjust opener may result in serious personal

injury from a closing garage door. Repeat test once a month and

adjust as needed.

Procedure: 

Place a 40mm obstacle (1) laid flat on the floor under the

garage door. Operate the door in the 

down 

direction. The door 

must

reverse on the obstruction. If the door 

stops

on the obstruction, it is

not travelling far enough in the 

down 

direction. Move Close Limit closer

to door.

When the door reverses on the 40mm obstacle, remove the

obstruction and run the opener through a complete travel cycle. Door

must not

reverse in closed position. If it does, adjust Limit and repeat

safety reverse test.
Place 20kg at the center of the door and ensure that the door will not

move up more than 500mm.

SAVE THESE INSTRUCTIONS

19

Attach Limit Switches

NOTE:

The limits must be installed as shown. If installed incorrectly the

unit will not function properly.

Close garage door by hand. Determine the position of the Close Limit

Switch (1) (Long wire) by aligning the centre of trolley and the centre of

the Limit Switch. The Limit Switches are actuated by a magnet in the

Inner Trolley. Insert bottom tab (5) of Limit Switch (1) into bottom lip of

Rail (7). Insert top tab (4) under top lip of Rail (6). Lift limit assembly

against top lip of Rail and tighten screw (8) to secure Close Limit

Switch. Open garage door by hand to the full open position. Pull red

handle to open door past Inner Trolley. Determine the position of the

Open Limit Switch (3) (Short Wire) by aligning the centre of the Trolley

and the centre of the Limit Switch. Insert bottom tab (5) of Limit Switch

(1) into bottom lip of rail (7). Insert top tab (4) under top lip of rail (6).

Lift limit assembly against top lip of rail and tighten screw (8) to secure

Open Limit Switch. Insert wires for Limit Switch (9) into top channel of

Rail (10). Secure wires with wire clip. the wires must be secured so

they do not interfere with the travel of the Trolley. Activate remote, the

opener will operate and reconnect to the door automatically. Run

opener 2 full travel cycles. If the door reverses in mid travel go to

Setting the Force Section. Adjust Limit Switches as necessary to fully

open and close the door without reversing.

17

1

Summary of Contents for Econolift ML500

Page 1: ...e to comply with the installation instructions and the safety warnings may result in serious personal injury and or property and remote control opener damage Please save these instructions for future reference Econolift Econolift SECTIONAL TILTING GARAGE DOOR OPENER ML500 Econolift Sectional Tilting Garage Door Opener ...

Page 2: ... injury from a closing garage door may result from misuse of the opener Activate opener ONLY when the door is in full view free of obstructions and opener is properly adjusted No one should enter or leave the garage while the door is in motion Do not allow children to play near the door Use manual release only to disengage the trolley and if possible ONLY when the door is closed Do not use the red...

Page 3: ...ssembly 5 on a piece of wood 6 until Rail sections are flush Repeat for final Rail section 5 Assemble Cable Pulley Bracket Insert Carriage Bolt 1 though square hole in Cable Pulley Bracket 4 Remove Chain Cable assembly 3 from carton Wrap Cable around Cable Pulley 2 and insert Pulley into Bracket NOTE Make sure the Bracket is assembled in position shown Slide pin 5 through holes in Cable Pulley Bra...

Page 4: ...Bolts Mark length on ceiling starting at the Header Wall along this point is where the unit will be mounted Lift door to full open position rest opener on door Insert Square Head Screws A into Rail assembly B approximately 120mm from end of Rail near motor unit Slide Hanging Brackets on to Square Head Screws and secure Brackets with Nuts 5 In this process the Square Head Screws hook into slots on ...

Page 5: ...r may result in serious personal injury from a closing garage door Repeat test once a month and adjust as needed Procedure Place a 40mm obstacle 1 laid flat on the floor under the garage door Operate the door in the down direction The door must reverse on the obstruction If the door stops on the obstruction it is not travelling far enough in thedown direction Move Close Limit closer to door When t...

Page 6: ... 2 minutes when power is connected After 2 1 2 minutes it will turn off 21 1 Install Safety Infrared Beam Kit Optional See accessories After opener has been installed and adjusted optional IR beams can be installed Instructions are included with this device It uses an invisible beam which when broken by an obstruction causes a closing door to open and prevents an open door from closing and is stro...

Page 7: ... installation instruction warning on page 1 Try a new battery If you have two or more remotes and only one operates review receiver programming procedures in Step 21 Is there a build up of ice or snow under door The door may be frozen to ground Remove any obstruction The garage door spring may be broken Have it professionally replaced 2 Remote has short range Is battery installed Try a new one Cha...

Page 8: ... warranty is expressly instead of all other warranties express or implied including any implied warranty of merchantability or fitness for a particular purpose and notwithstanding any course of dealing between the parties or custom and usage in the trade to the contrary 8 No other liability Subject to the warranty in clause 3 and to clause 6 B D shall not be subject to nor incur and the purchaser ...