B
5
4
4
A
1
3
4
2
3
2
4
4
1
2
Connect Door Arm to Trolley
A. Preferred Installation:
Disconnect Trolley by pulling on the red handle and slide towards door.
With door closed connect Straight Door Arm (5) to Trolley (4) with Bolt
(3), secure with Nut (1). Connect Curved Door Arm (2) to Door Bracket
with Bolt (3) Secure with Nut (1). Align Straight and Curved Door Arms
with a 2 hole overlap connect with Bolt (3), secure with Nut (1), If
Straight Door Arm (5) is too long, cut the end of the Door Arm.
B. Where extra travel distance is required:
With door closed connect Curved Door Arm (2) to Door Bracket
with Bolt (3), secure with Nut (1). Lift Curved Door Arm (2) to meet
Trolley, connect door arm to Trolley with Bolt (3), secure with Nut (1).
Connect Electric Power
To avoid installation difficulties, do not run the garage door
opener until instructed to do so.
Plug the opener into electric outlets as specified by local wiring codes.
The opener light will turn on when power is connected and remain on
for 2-1/2 minutes.
16
A
B
1
3
1
2
3
1
4
3
2
2
3
3
1
1
5
1
2
3
1
3
4
5
3
1
4
8
5
7
9
6
2
Setting the Force
The Force is programmed to operate most doors, however, if Limits are
not able to be set, or the door reverses during normal operation follow
this procedure: Locate the Program Button (1) on the left side panel of
unit (2). Push the Program Button twice to enter unit into Auto-Force
Adjustment Mode. The green LED will flash slowly. Activate unit with
remote and run the unit to the Open Limit. Activate unit again to run the
unit to the Closed Limit. The door must travel through a complete cycle
up and down in order for the Force to be set properly. If the unit stops
before it reaches the Open or Close Limit repeat the process. The
green LED will stop flashing when the Force has been learnt.
18
1
2
Test the Safety Reverse System
The safety reverse system test is important. Garage door must
reverse on contact with a 40mm obstacle laid flat on the floor.
Failure to properly adjust opener may result in serious personal
injury from a closing garage door. Repeat test once a month and
adjust as needed.
Procedure:
Place a 40mm obstacle (1) laid flat on the floor under the
garage door. Operate the door in the
down
direction. The door
must
reverse on the obstruction. If the door
stops
on the obstruction, it is
not travelling far enough in the
down
direction. Move Close Limit closer
to door.
When the door reverses on the 40mm obstacle, remove the
obstruction and run the opener through a complete travel cycle. Door
must not
reverse in closed position. If it does, adjust Limit and repeat
safety reverse test.
Place 20kg at the center of the door and ensure that the door will not
move up more than 500mm.
SAVE THESE INSTRUCTIONS
19
Attach Limit Switches
NOTE:
The limits must be installed as shown. If installed incorrectly the
unit will not function properly.
Close garage door by hand. Determine the position of the Close Limit
Switch (1) (Long wire) by aligning the centre of trolley and the centre of
the Limit Switch. The Limit Switches are actuated by a magnet in the
Inner Trolley. Insert bottom tab (5) of Limit Switch (1) into bottom lip of
Rail (7). Insert top tab (4) under top lip of Rail (6). Lift limit assembly
against top lip of Rail and tighten screw (8) to secure Close Limit
Switch. Open garage door by hand to the full open position. Pull red
handle to open door past Inner Trolley. Determine the position of the
Open Limit Switch (3) (Short Wire) by aligning the centre of the Trolley
and the centre of the Limit Switch. Insert bottom tab (5) of Limit Switch
(1) into bottom lip of rail (7). Insert top tab (4) under top lip of rail (6).
Lift limit assembly against top lip of rail and tighten screw (8) to secure
Open Limit Switch. Insert wires for Limit Switch (9) into top channel of
Rail (10). Secure wires with wire clip. the wires must be secured so
they do not interfere with the travel of the Trolley. Activate remote, the
opener will operate and reconnect to the door automatically. Run
opener 2 full travel cycles. If the door reverses in mid travel go to
Setting the Force Section. Adjust Limit Switches as necessary to fully
open and close the door without reversing.
17
1