Fan and heating are disabled but the machine remains on.
The alarm is automatically deactivated when all normal conditions are restored (closing the ther-
mal relay contact) or by cycling power to the ironer.
This alarm is generally caused when the fan is clogged with lint or debris.
6.6.3
AL5 - Inverter Fault
When the inverter faults, the buzzer is activated for 1 minute and AL5 appears on the display:
The machine powers off automatically.
The alarm can be deactivated by restarting the machine or removing main power, waiting 1 minute
and turing main power on again.
This fault may be due to roller motor overload caused by machine jamming or a blockage in the
roller motor.
6.6.4
AL6 - Flame Failure
The alarm is only used when the machine is configured for gas heating.
When the heater is ignited, or is in process of igniting, and if the activated gas device does not
generate a flame, the buzzer is activated for 1 minute and AL6 appears on the display.
The ignition control system remains active and the machine remains powered on.
To try and reignite the burner, press the + and - buttons simultaneously after the alarm stops.