Table 3.2: DE Series Compressed Air Requirements
Compressed Air Pressure
Minimum
70 psi
Nominal
80 psi
Maximum
90 psi
Air connection to system — 1/8-inch N.P.T.
No air regulation or filtration is provided with the dryer. External regulator and filtration must
be provided. It is suggested that a filter be added to the compressed air line just before the dryer
connection (B&C P/N 270-318 or locally obtained). This is necessary to insure that clean and dry
air is delivered to the equipment. Wet and dirty air will cause rapid deterioration and failure of air
system components.
3.5.1
Steam Damper Operation
The steam damper, as shown in figure 3.9 on page 19 allows the coil to stay constantly charged
eliminating repeated expansion and contraction. When the damper is opened, the air immediately
passes through the already hot coil, providing instant heat to start the drying process. When the
damper is closed, ambient air is drawn directly into the basket (tumbler), allowing a rapid cool
down.
The diagrams show the damper in the heating (open) mode, allowing heat into the drying cylinder
and in the cool down (closed) mode, pulling ambient air directly into the basket (tumbler) without
passing through the coils.
Note: With the dryer off or with no air supply, the damper is in the cool down mode.
3.5.2
Steam Damper Air Piston Adjustment
Although the damper operation was tested and adjusted prior to shipping at 80 psi, steam damper
operation must be checked before the dryer is put into operation. If damper air adjustment is
necessary, locate flow control valve and make necessary adjustments. See figure 3.10 on page 19
for details.
3.6
Exhaust Requirements
For best results, install the machine near an outside wall in order to keep the exhaust duct length
as short as possible, and to provide a source of make-up air. The rear of the dryer should not
18
Summary of Contents for DE Series
Page 1: ...Dryer DE Series Installation and Operation Manual March 17 2014 Revision 1 7 ...
Page 5: ...Figure 1 1 DE Product Family 2 ...
Page 12: ...Figure 3 1 DE Gas General Specifications 9 ...
Page 13: ...Figure 3 2 DE 30 Utility Connections 10 ...
Page 14: ...Figure 3 3 DE 50 75 Utility Connections 11 ...
Page 15: ...Figure 3 4 DE 120 Utility Connections 12 ...
Page 16: ...Figure 3 5 DE 170 Utility Connections 13 ...
Page 25: ...Figure 3 14 DE Series Bulkhead Installation Details 22 ...
Page 33: ...Figure 5 1 Simplified Call for Heat Path 30 ...
Page 34: ...Figure 5 2 Detailed Call for Heat Path 31 ...
Page 35: ...Figure 5 3 Call for Heat Path Schematic Figure 5 4 Mechanical Timer Start Path 32 ...