Routine Maintenance
34
Maintenance
5. Remove back panel and check overflow
hose and drain hose for leaks.
6. Unlock the hinged lid and check the
supply dispenser hoses and hose
connections.
7. Clean inlet hose filter screen:
a. Turn water off and allow valve to
cool, if necessary.
b. Unscrew inlet hose and remove
filter screen.
c. Clean with compressed air and
reinstall. Replace if worn or damage.
8. Tighten motor mounting bolt lock nuts
and bearing bolt lock nuts, if
necessary.
9. Use compressed air to clean lint from
motor.
10. Clean external water and steam filters.
Quarterly
NOTE: Disconnect power to the machine
before performing the quarterly
maintenance procedures.
1. Tighten door hinges and fasteners, if
necessary.
2. Tighten anchor bolts, if necessary.
3. Check all painted surfaces for bare metal
(matching paint is available from the
manufacturer.)
a. If bare metal is showing, paint with
primer or solvent-based paint.
b. If rust appears, remove it with sand
paper or chemical means. Then
paint with primer or solvent-based
paint.
4. Clean steam filter, where applicable. See
picture of steam filter.
NUT
ELEMENT
1. Turn off steam supply and allow time
for the valve to cool if necessary.
2. Unscrew nut.
3. Remove element and clean.
4. Replace element and nut.
Summary of Contents for HP series
Page 2: ......
Page 15: ...Installation HP 65 Technical Specifications 14 ...
Page 16: ...Installation HP 125 Technical Specifications 15 ...
Page 39: ......