![B&B VESR901 User Manual Download Page 32](http://html1.mh-extra.com/html/bandb/vesr901/vesr901_user-manual_3088395032.webp)
32
the number of network packets, but increase the amount of time to receive
characters. Smaller values may increase the number of network packets, but
decrease the amount of time to receive characters. The range is 1 through 65535.
IP ADDRESS
Software or hardware attempting to access the serial server via the network must
know the
IP Address
of the server. In DHCP mode (factory default), the serial server
requests and receives a dynamic IP address from a DHCP server when it first
connects to the network. If there is not a DHCP Server on your network, this device
will automatically default to IP Address
169.254.102.39
. If the serial server is unable
to connect to your network using this address, there are two methods to manually
configure the IP Address.
1.
Method One: Change your PC Network to Match the Serial Server
a.
Open the network connection on your PC
b.
Click on Internet Protocol (TCP/IP) and click <Properties>.
Change the parameters to the following:
IP Address = 169.254.102.1
Subnet Mask = 255.255.255.0
Default Gateway = 169.254.102.100
Summary of Contents for VESR901
Page 1: ...VESR9xx Serial servers...
Page 51: ...51 APPENDIX C DIMENSIONAL DIAGRAMS Dimensional Diagram of a VESR901 Serial Server...
Page 52: ...52 Dimensional Diagram of a VESR902D Serial Server...
Page 53: ...53 Dimensional Diagram of a VESR902T Serial Server...
Page 54: ...54 Dimensional Diagram of a VERR92x Serial Server...
Page 56: ...56 Terminal RS 422 485 4 Wire RS 485 2 Wire A TDA Data A B TDB Data B C RDA D RDB E GND GND...