MOUNTING HARDWARE
VESR9xx Serial Server modules can be DIN rail mounted. The DIN mounting clip and
spring is included on each module.
DIN Clip on a Serial Server Module
SERIAL SERVER SETUP AND CONNECTIONS
This section describes how to setup and connect VESRxx Serial Servers.
Note: In this section devices to be connected to the serial server’s serial connection are
simply referred to as the “serial device”.
CONNECTING THE POWER SUPPLY
Connect a
DC power supply
to the power terminals on the top of the serial server.
Polarity of the wires is indicated on the label on the side of the serial server.
Acceptable voltages are between 10 VDC and 48 VDC. The power supply must be
capable of supplying 4 Watts for VESR90x models and 6.0 Watts for VESR92x models.