46
Manual Documentation Number: ZPXXx-XXXXx-XR-0812
B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 –
www.bb-elec.com
B&B Electronics – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 –
www.bb-europe.com
SB (Stop Bits) Command
<Serial Interfacing> Set/Read
the number of stop bits in the
RF data packets.
SH (Serial Number High)
Command
<Diagnostics> Set/Read the
serial number high word of the
module.
SL (Serial Number Low)
Command
<Diagnostics> Set/Read the
serial number low word of the
module.
AT Command: ATSB
Binary Command: 0x36 (54 decimal)
Parameter Range: 0
– 1
Parameter
Configuration
0
1 stop bits
1
2 stop bits
Default Parameter Value: 0
Number of bytes returned: 1
Minimum Firmware Version Required: 4.2B
AT Command: ATSH
Binary Command: 0x25 (37 decimal)
Parameter Range: 0
– 0xFFFF [read-only]
Number of bytes returned: 2
Related Commands: SL (Serial Number Low)
Minimum Firmware Version Required: 4.27C
AT Command: ATSH
Binary Command: 0x26 (38 decimal)
Parameter Range: 0
– 0xFFFF [read-only]
Number of bytes returned: 2
Related Commands: SH (Serial Number High)
Minimum Firmware Version Required: 4.27C