CB (Connection Duration
Timeout) Command
<Networking & Security>
Set/Read the maximum amount
of time an exclusive
connection between a base and
remote module in a point-to-
multipoint network is sustained.
The remote module will
disconnect when this timeout
expires.
CC (Command Sequence
Character) Command
<Command Mode Options> CC
Command is used to set the
ASCII character to be used
between Guard Times of the AT
Command Mode Sequence
(BT+ CC + AT). The AT
Command Mode Sequence
activates AT Command Mode
(from Idle Mode).
Refer to the AT Commands section to view the default AT Command Mode
sequence.
CD (DO3 Configuration)
Command
<Serial Interfacing> CD
Command is used to redefine the
behavior of the DO3 (Data Output
3)/RX LED line.
CE (Connection Inactivity
Timeout) Command
<Networking & Security>
Set/Read the duration of
inactivity that will cause a break
in a connection between
modules. The base module
will disconnect when no payload
has been transferred for the time
specified by the CE parameter.
Binary Command: 0x33 (51 decimal)
Parameter Range:
0x01
– 0xFFFF
[x 100 milliseconds]
Default Parameter Value: 0x28 (4d seconds)
Number of bytes returned: 2
Related Commands: CE (Connection Inactivity
Timeout), DC (Disconnect), MD (RF Mode)
Minimum Firmware Version Required: 4.30
AT Command: ATCC
Binary Command: 0x13 (19 decimal)
Parameter Range:
0x20
– 0x7F
Default Parameter Value: 0x2B (ASCII “+” sign)
Number of bytes returned: 1
Related Commands: AT (Guard Time After), BT
(Guard Time Before)
AT Command: ATCD
Binary Command: 0x28 (40 decimal)
Parameter Range: 0
– 4
Parameter
Configuration
0
RX LED
1
Default high
2
Default low
3
(reserved)
4
Assert only when packet
addressed to module sent
Default Parameter Value: 0
Number of bytes returned: 1
Minimum Firmware Version Required: 4.2B
AT Command: ATCE
Binary Command: 0x34 (52 decimal)
Parameter Range:
0
– 0xFFFF
[x 10 milliseconds]
Default Parameter Value: 0x64 (1d second)
Number of bytes returned: 2
Related Commands: CB ( Connection Duration
Timeout), DC (Disconnect), MD (RF Mode)
Minimum Firmware Version Required: 4.30