Power over Ethernet is a technique (defined by the IEEE802.3af standard) for 
providing  power  to  Ethernet  enabled  devices  over  standard  Category  5e 
cabling. Two techniques (Alternative A and Alternative B) are defined by the 
standard and supported by the PES1A/PESV1A.  

Alternative  A  implements  a  simplex,  or  „phantom  feeding‟  method  for 
delivering power to the end device. Power is carried on the same conductors 
as  data.  Cabling  for  standard  10BaseT  and  100BaseTX  Ethernet  (typically 
Category  5  cable  with  RJ-45  connectors)  uses  two  data/signal  pairs.  The 
power sourcing equipment (PSE) applies positive DC voltage (simplexed) to 
pins 3 and 6. Negative voltage is applied to pins 1 and 2. The powered device 
(PD) derives the power from these lines.  

Alternative  B  carries  power  over  spare  wire  pairs  in  the  cable.  The  power 
sourcing equipment applies positive voltage to pins 4 and 5. Negative voltage 
is applied to pins 7 and 8. 

Operating  voltage  is  typically  48  volts  but  may  vary  from  44  volts  to  57 
volts.  

Power

Sourcing

Equipment

(PSE)

Powered

Device

(PD)

Data Pair

Data Pair

6

2

Device with Power Source

Data Pair

Data Pair

Powered End Station

6

2

Negative (-)

Po)

Negative (-)

Po)

3

3

1

1

 

Figure 23.  Power over Ethernet Alternative A 

Summary of Contents for PES1A

Page 1: ...0 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com M Mi in ni i P PO OE E E Et...

Page 2: ...12m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland Ph 353 91...

Page 3: ...dquarters B B Electronics Mfg Co Inc 707 Dayton Road Ottawa IL 61350 USA Phone 815 433 5100 General Fax 815 433 5105 Website www bb elec com Sales e mail orders bb elec com Fax 815 433 5109 Technical...

Page 4: ......

Page 5: ...ncluding photography recording or any information storage and retrieval system without written consent Information in this manual is subject to change without notice and does not represent a commitmen...

Page 6: ......

Page 7: ...PACKAGE CHECKLIST 5 INDICATORS SWITCHES AND CONNECTORS 6 Link Integrity LED Yellow 6 Network Activity LED 6 Reset Switch 6 Voltage Output Selector Switch PESV1A only 6 Ethernet Port Connector 7 Seria...

Page 8: ...ile Settings 18 Basic Serial Settings 23 Advanced Serial Settings 24 CONFIGURING ALARMS AND NOTIFICATION 24 Alarm Notification Settings 24 Alarm Conditions 24 Alarm Destinations 25 CHAPTER 6 MANAGING...

Page 9: ...91 792445 www bb europe com CHAPTER 8 USING REALPORT 35 Configuring the IP Address 35 Configuring the Serial Port for RealPort 35 Adding a Virtual COM Port using RealPort 36 Removing a Virtual COM Por...

Page 10: ...m iv B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland Ph 353 9...

Page 11: ...point of sale warehousing and banking equipment directly into Ethernet networks Both models feature Power over Ethernet PoE operation and the PESV1A provides a switch selectable voltage output to pow...

Page 12: ...al server In this mode the PES1A PESV1A is configured as a TCP or UDP server The socket program running on the PC establishes a communication connection The data is sent directly to and from the seria...

Page 13: ...lowing communications profiles Terminal Mode allows you to connect a PC running terminal software to the PES1A PESV1A serial port and communicate with the PES1A PESV1A via a command line interface Mod...

Page 14: ...SV1A 0712m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland Ph...

Page 15: ...er rv vi ie ew w Package Checklist PES1A PESV1A PoE Ethernet to RS 232 Converters are shipped with the following items included The PES1A or PESV1A module A printed version of this user manual A prin...

Page 16: ...the network Network Activity LED When the green LED located on the Ethernet jack is flashing it indicates data is being sent across the network Figure 4 LED Indicators on the PES1A Reset Switch The R...

Page 17: ...D RD TRS CTS DTR DCD DSR and GND signal lines Use a standard serial cable if connecting to a DCE use a null modem crossover cable if connecting to a DTE Refer to Appendices D E and F for connection pi...

Page 18: ...iguration is accomplished over the network or via a direct connection see below using the Web Configuration and Management Interface Power over Ethernet PoE Power is supplied to your PES1A PESV1A from...

Page 19: ...he PES1A PESV1A Midspan PoE Power Source Switch or Hub Figure 7 Connection using Midspan Power Source Configuration Connections Your PES1A PESV1A converter typically is configured over the network con...

Page 20: ...PESV1A 0712m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland...

Page 21: ...this manual Quick Start guide 2 Set up the Hardware Connect your PC to the network Connect the PES1A PESV1A serial port to your serial device Use a serial cable if it is DCE null modem cable if it is...

Page 22: ...port TCP Server UDP server Serial Bridge etc Configure the serial port settings for the selected Port Profile E g In TCP Sockets select client or server TCP port numbers etc Also configure baud rate d...

Page 23: ...IP address using static IP addressing if necessary Your PES1A PESV1A comes from the factory configured to obtain an IP address dynamically or failing that to generate its own IP address using the APIP...

Page 24: ...g the discovery software or you can open the Web Configuration and Management Interface and do it there See Configuring Network Settings later in the next chapter 1 To change the IP address of the PES...

Page 25: ...face To login open your browser type the IP address of your PES1A PESV1A converter into the address bar and press Enter The Login page will appear 2 Enter your Username and Password then click Login T...

Page 26: ...he Configuration and Management homepage Clicking Help on any page of the Configuration and Management Interface opens topics specific to that page After logging in if there is no activity for a perio...

Page 27: ...ddress to itself using the Automatic Private IP Addressing APIPA protocol You can re configure the PES1A PESV1A for static IP address by selecting Use the following IP address and assign the IP addres...

Page 28: ...ts parity stop bits You will have to configure these parameters to set up your system for the type of operation required and to match the parameters of the serial device to which the PES1A PESV1A is c...

Page 29: ...e PES1A PESV1A you create a virtual COM port on the PC When your application sends data to this port RealPort redirects the data across the network to the PES1A PESV1A The PES1A PESV1A passes the data...

Page 30: ...his is also referred to as reverse telnet Network devices initiating connections must be configured with the IP address of the PES1A PESV1A and the TCP port number associated with its serial port Afte...

Page 31: ...ect UDP Sockets to implement Direct IP Mode using UDP protocol When using UDP Sockets your converter can be configured as a UDP server or UDP client UDP Server Settings If your PES1A PESV1A is configu...

Page 32: ...P Server Settings UDP Client Settings If your PES1A PESV1A is configured as a UDP client you can automatically distribute serial data from you PES1A PESV1A to many devices at the same time This is som...

Page 33: ...s set up to communicate through a modem the serial device can be connected to the PES1A PESV1A and communication occurs over the network The PES1A PESV1A emulates modem responses to and from the seria...

Page 34: ...e current alarm settings and allows you to configure them It contains two sections Alarm Notification Settings and Alarm Conditions Note In the PES1A PESV1A GPIO lines are permanently configured as RS...

Page 35: ...the condition of some RS 232 hardware handshake lines For assistance in implementing this feature contact B B Electronics Technical Support at 815 433 511 or support bb elec com To Send alarms based...

Page 36: ...ation Number PES1A PESV1A 0712m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranm...

Page 37: ...PES1A PESV1A the SNMP Contact person a text description of the Location of the PES1A PESV1A and the Device ID number Simple Network Management Protocol SNMP Settings The SNMP Settings page allows you...

Page 38: ...other users and configure the specific rights of each Non administrators can also set up new users access and permissions if they have permission but a user cannot set another user s permission level...

Page 39: ...anted to the user See the online help for more information on these choices Managing Serial Ports and Connections The Management section of the Web Configuration and Management Interface provides info...

Page 40: ...ES1A PESV1A 0712m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ire...

Page 41: ...htm or index html file will automatically load that page upon logging into the PES1A PESV1A Backup Restore The Backup Restore page allows you to backup the current configuration settings on your PES1A...

Page 42: ...bb europe com System Information The System Information page displays information about your PES1A PESV1A General Model MAC Address Firmware Version Boot Version POST Version CPU Utilization Up Time...

Page 43: ...350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Figure 17 Serial Port Dia...

Page 44: ...0 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com Reboot The...

Page 45: ...rts configuring your serial port with the RealPort profile you must use RealPort to configure those ports on your PC Once you have configured a new virtual COM VCOM port using RealPort application sof...

Page 46: ...dialog appears listing the IP Address MAC Address and Model of all devices on the network To identify your PES1A PESV1A compare the MAC address listed with the MAC address on the label on your PES1A P...

Page 47: ...at appears select the COM port number to be assigned to the PES1A PESV1A Click Next A progress screen will appear 7 When the process is complete click Finish Windows 98 ME NT 4 0 1 Follow the readme t...

Page 48: ...PESV1A 0712m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Ireland...

Page 49: ...Ltd Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com A Ap pp pe en nd di ix x A A D De ef fa au ul lt t C Co on nf fi ig gu ur ra at ti io on n S...

Page 50: ...r PES1A PESV1A 0712m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway...

Page 51: ...nts Class 3 Power over Ethernet PoE Power Consumption Class 3 device for PoE configuration Power Output PESV1A only 5 9 or 12VDC 4W maximum slide switch selectable Connector is pluggable two position...

Page 52: ...s Direct IP TCP or UDP Sockets Virtual COM Port RealPort Paired Mode serial bridge serial tunneling Terminal Modem Emulation Custom Configuration Method Uses any web browser via built in web server Cu...

Page 53: ...Westlink Commercial Park Oranmore Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com A Ap pp pe en nd di ix x C C D Di im me en ns si io on na al l D Di ia ag gr ra am ms s Figure 19...

Page 54: ...1A PESV1A 0712m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Irela...

Page 55: ...Galway Ireland Ph 353 91 792444 Fax 353 91 792445 www bb europe com A Ap pp pe en nd di ix x D D R RS S 2 23 32 2 C Co on nn ne ec ct ti io on ns s DB 9M Pin Signal RS 232 DTE 1 Carrier Detect DCD In...

Page 56: ...A PESV1A 0712m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Irelan...

Page 57: ...353 91 792444 Fax 353 91 792445 www bb europe com A Ap pp pe en nd di ix x E E N Ne et tw wo or rk k C Co on nn ne ec ct ti io on ns s Figure 22 Pin out for an Ethernet Cable showing PoE RJ 45 Pin Si...

Page 58: ...A PESV1A 0712m B B Electronics Mfg Co Inc 707 Dayton Rd PO Box 1040 Ottawa IL 61350 Ph 815 433 5100 Fax 815 433 5104 www bb elec com B B Electronics Ltd Westlink Commercial Park Oranmore Galway Irelan...

Page 59: ...ng method for delivering power to the end device Power is carried on the same conductors as data Cabling for standard 10BaseT and 100BaseTX Ethernet typically Category 5 cable with RJ 45 connectors us...

Page 60: ...Power Source Data Pair Data Pair Powered End Station 6 2 Negative Positive Negative Positive 7 8 4 5 7 8 4 5 1 1 3 3 Figure 24 Power over Ethernet Alternative B DECLARATION OF CONFORMITY Manufacturer...

Reviews: