9
End to End Connection
Switch
McPC TX/FX
Half-Duplex
Manually Configure HDX
Auto Negotiation OFF
Full-Duplex
Manually Configure FDX
Auto Negotiation OFF
Full-Duplex
Auto negotiation ON
Auto Negotiation ON
Configure Auto Negotiation on an iMcV-LIM by adjusting the DIP Switch setting
(for unmanaged modules) or via the management software. Refer to the
diagrams in this manual for switch location and settings.
Installation Troubleshooting
During installation, first test the fiber and twisted pair connections with all
troubleshooting features disabled, then enable these features, if desired, just
before final installation. This will reduce the features’ interference with testing.
When working with units where the features cannot be disabled, it is necessary to
establish BOTH the twisted pair and fiber connections before the link LEDs will
light.
To test a media converter by itself, first make sure to have an appropriate fiber
patch cable, then follow these steps to test:
1. Connect the media converter to the twisted pair device with a twisted
pair cable.
2. Loop a single strand of fiber from the transmit port to the receive port of
the media converter.
3. Verify that there are both twisted pair and fiber link (see LEDs, below)
on the media converter.
Make sure to use the appropriate twisted pair cable, and have the
crossover/pass-through switch set correctly.
When connecting 10 Mbps iMcV-PIM Media Converters, the end devices must be
set to Force mode.
Specifications
Power Consumption (Typical @ 5V):
iMcV-PIM (-10): 600 mA
IMcV-LIM: 800 mA
iMcV-S2MM/M2MM/S2SM: 620 mA
Operating Temperature
32° to 122° F (0° to 50° C)
Storage Temperature
0° to 160° F (-20° to +70° C)
Humidity