ESW10x Series 0712-ds - 2/3
©2011 B&B Electronics. All rights reserved
www.bb-elec.com
[email protected] [email protected]
International Office:
707 Dayton Road PO Box 1040 Ottawa, IL 61350 USA 815-433-5100 Fax 433-5104
European Office: Westlink Commercial Park Oranmore Co. Galway Ireland +353 91 792444 Fax +353 91 792445
PR
O
D
U
C
T
INF
ORM
A
TIO
N
B
&
B
ELE
C
T
R
ON
ICS
Specifications
Technology
Standards:
IEEE802.3, 802.3u, 802.3x
Processing Type:
Store and forward with IEEE802.3x full duplex, non-blocking flow control
Flow Control:
IEEE802.3x flow control, back pressure flow control
Packet buffer memory:
64K bytes
Address Table Size
2K MAC Addresses
Interface
RJ45 Ports:
10/100BaseT(X) auto negation, Full/Half duplex, auto MDI/MD-X
Fiber Ports:
100BaseFX, (multi-mode or single
–mode with LC connectors)
LED Indicators:
Power, (Link / Speed / Activity for each port)
Fiber Optics
Fiber Type
Distance
Wavelength
Transmit Power
Receive Sensitivity
Multi-mode
2 km
1310 nm
Neg. 23.5 to Neg. 14 dBm
≤ Neg. 35 dBm
Single-mode
20 km
1310 nm
Neg. 15 to Neg. 8 dBm
≤ Neg. 35 dBm
Power
Environmental
Input Voltage
12 to 36 VDC and 10 to 24 VAC
Op. Temperature
-10 to 60 C (14 to 140 F)
Power Consumption
4.00 W Max
Storage Temperature -40 to 80 C (-40 to 176 F)
Humidity
10 to 95% Non-condensing
Input Connection
Removable Terminal Block
MTBF
200,000 hours
Protection
Reverse Polarity Protection
MTBF Calculation
Parts count reliability prediction
Mechanical
Regulatory Approvals
Enclosure
IP30 DIN mount metal case
CE, FCC,
Dimensions (5 ports)
H 100mm x W 25mm x D 75mm
( 3.94in x 0.98in x 2.95in)
RoHS
Dimensions (8 ports)
H 145mm x W 24mm x D 75mm
(5.71in X 0.94in x 2.95in)
Hazardous Locations
NEW
UL/cUL Class I Div 2 Groups A,B,C, and D
Installation
35 mm DIN or 6 way panel mount
Specifications
–Level 3, EN 61000-6-2: 2006 Generic Standards for (Heavy) Industrial environments
Test
Description
Test Level
Level
EN 55022: 2006 + A1:2007
Class B Emissions
EN 61000-4-2: 2009
Electro-Static Discharge (ESD)
Enclosure Contact
6kV
3
Enclosure Air
8kV
3
EN61000-4-3:2006+A1:2008
Radiated Field Immunity (RFI)
Enclosure Ports
10V/m
3
EN61000-4-4:2004
Burst (Fast Transient)
Signal Ports
3
DC Ports
2kV
3
EN61000-4-5:2006
Surge
Signal Ports
1kV
3
DC Power Ports
2kV
3
EN61000-4-6: 2009
Induced (Conductive) RFI
Signal Ports
10 V RMS
3
DC Power Ports
10 V RMS
3
Environmental Specifications
Test
Description
Test Level
Level
IEC60068-2-6
Vibration
Test Fc
2G
-----
IEC60068-2-27
Shock
Test Ea
30G
-----
IEC 60068-2-32
Free Fall
-----
Operating Temperature
-10 to 60C
14 to 140F
Storage Temperature
-40 to 80C
-40 to 176F
Humidity
10 to 95% Non-condensing