Installation and Operations Manual
— Model 400E Series
13
B&B ARMR
A Division of B&B Roadway and Security Solutions 0400E-9001 Rev J
Description
Terminal
Block
OPEN I1
CLOSE I2
LOCK PIN UP (450) I3
CLOSED LIMIT A I4
OPEN LIMIT A I5
SAFETY DEVICES (ALL) I6
STOP (NORMALLY CLOSED) I7
ECO I9
ECO RESET I10
CLOSED LIMIT B I11
OPEN LIMIT B I12
LOCK PIN DOWN (450) I13
BACK SENSOR I14
2.5.4
Terminate field output wiring for optional components.
Traffic Lights
Terminal Block
Common 120VAC Neutral (white
terminal blocks)
GREEN/AMBER Q6
RED Q7
Control Panel Indicators
Terminal Block
0V 0V (black terminal blocks)
GREEN INDICATOR Q8
RED INDICATOR Q9
ECO Q10
OPTIONAL DEVICES
Loop Detector
– One loop detector and socket come pre-wired for use as a safety. The
loop wires connect to terminals 7 & 8 on the loop detector socket. The safety loop is
wired into the safety input in the ECU.
IR Beam
– It is suggested that infrared safety beams are used as an additional layer of
safety. An IR beam receiver’s Normally Open output may be wired into the safety input
in the ECU.
Edge Detector
– A closing edge detector’s receiver may be wired into the safety input in
the ECU, and an optional opening edge detector’s receiver may be wired into the
Backsensor input in the ECU.
Card Reader
– A 3
rd
party entry access device such as a badge reader may be used to
open the gate. A normally open output on such a device may be wired to the open input
in the ECU.